B064 SERIES SC CODE DESCRIPTIONS SC100: Scanning System



SC No.

Symptom

Possible Cause


101


D
Exposure Lamp Error





At trigger on, the lamp was not detected on.

x Exposure lamp defective x Lamp regulator defective x Exposure lamp connector defective x Dirty standard white plate
x Dirty scanner mirror or scanner mirror out of position
x SBU board defective x SBU connector defective x IPU defective



120


D
Scanner home position error 1





The scanner HP sensor does not detect the on condition during initialization or copying.

x BCU, SDRB (Scanner Driver Board) defective.
x Scanner motor defective
x Harness between BCU, SDRB, scanner motor disconnected.
x Scanner HP sensor defective. x Harness between scanner HP sensor and BCU disconnected.
x Scanner wire, timing belt, pulley, carriage installation incorrect.



121


D
Scanner home position error 2





The scanner HP sensor does not detect the off condition during initialization or copying.

x BCU, SDRB (Scanner Driver Board) defective.
x Scanner motor defective.
x Harness between BCU, SDRB, scanner motor disconnected.
x Scanner HP sensor defective.
x Harness between scanner HP sensor and BCU disconnected.
x Scanner wire, timing belt, pulley, carriage installation incorrect.



122


D
Scanner home position error 3





The scanner home position sensor does not detect the on condition during original scanning.

x BCU, SDRB (Scanner Driver Board) defective.
x Scanner motor defective.
x Harness between BCU, SDRB, scanner motor disconnected.
x Scanner HP sensor defective. x Harness between scanner HP sensor and BCU disconnected.
x Scanner wire, timing belt, pulley, carriage installation incorrect.








SC No.

Symptom

Possible Cause


123


D
Scanner home position error 4





The scanner home position sensor does not detect the off condition during original scanning.

x BCU, SDRB (Scanner Driver Board) defective.
x Scanner motor defective.
x Harness between BCU, SDRB, scanner motor disconnected.
x Scanner HP sensor defective. x Harness between scanner HP sensor and BCU disconnected.
x Scanner wire, timing belt, pulley, carriage installation incorrect.



143


D
SBU auto adjust error





Automatic adjustment of the SBU fails when the machine is switched on.

x Exposure lamp defective. x Exposure lamp regulator defective.
x Harness between exposure lamp and lamp regulator is disconnected.
x White plate installed incorrectly or is dirty.
x Scanning mirrors of the exposure unit are dirty or out of position. x SBU board defective. x VIB board defective.
x Harness between SBU, VIB disconnected.
x Harness between VIB, BCU disconnected. x IPU defective x BCU defective



144


D
SBU transmission error





After the SBU switches on, the BCU detects one of the following conditions on the SBU:
x 1 s after power on, the SYDI signal does not go high, even after 1 retry.
x 1 s after power on, the SYDI signal goes high, but the SBU ID could not be read after 3 attempts.

x SBU defective. x VIB defective
x Harness (40-pin shielded) between the SBU, VIB is disconnected.
x Harness (shielded cable) between the VIB, BCU is disconnected.
x IPU defective












SC No.

Symptom

Possible Cause


181


D
CIS lamp abnormal





After the CIS lamp trigger goes on, the CIS lamp is not detected on. Detecting the lamp on or off determines the peak white level value for shading correction. (If the peak level is determined to be below a certain level, the CIS lamp is judged to be off.)

x CIS lamp defective. x CIS power supply board defective. x Harness between lamp and power supply board is disconnected.
x Harness between CIS, ADF is disconnected.
x CIS exposure glass dirty. x White roller dirty or installed incorrectly. x CIS unit defective.
x PSU defective







183


D
CIS auto adjust error





Automatic adjustment of the CIS unit failed.

x CIS unit defective. x CIS exposure glass dirty.
x White roller dirty or installed incorrectly.
x PSU power supply (+5V, –12V) is abnormal.
x IPU defective



184


D
CIS transmission error





When the CIS is powered on, the ADF detects one of the following abnormal conditions on the CIS unit:
x The SOUT signal does not go high within 1 s after power on.
x The SOUT signal goes high within 1 s after power on, but the SBU ID cannot be read after 3 attempts.

x CIS unit defective.
x Harness between the CIS, ADF is disconnected.
x PSU power (5V) is abnormal. x BCU, IPU defective




SC300: Image Development System (1)



SC No.

Symptom

Possible Cause


300


D
Charge corona output error





The feedback voltage from the charge corona unit is detected too high 9 times.

x Charge corona power pack defective x Charge corona harness disconnected x Poor charge corona unit connection



303


D
Charge corona grid leak





When the high voltage is output to the corona grid, feedback voltage exceeds the prescribed value 9 times.

x Charge corona power pack defective x Charge corona harness disconnected x Poor charge corona unit connection



305


D
Charge corona wire cleaner error 1





The charge corona wire cleaner motor is detected: x Motor locks within 4 s after switching on, or does not lock within 30 s. x Motor locks within 10 s after reversing, or does not lock within 30 s.

x Charge corona wire cleaner motor defective x BCU board defective



306


D
Charge corona wire cleaner error 2





The current at the charge corona motor is detected less than 83 mA.

x Charge corona wire cleaner motor connector is defective or not connected.









When SC310~SC317 are logged, the machine halts without displaying the SC number. These SC codes log an abnormal condition at the potential sensor only when SP3901 (Auto Process Control) is set to on.




SC No.

Symptom

Possible Cause


310


C
Potential sensor calibration error 1





During drum potential sensor calibration, the drum potential sensor output voltage does not meet specification when test voltages (–100V, –800V) are applied to the drum.

x Potential sensor defective
x Potential sensor harness disconnected x Potential sensor connector defective or disconnected
x BCU defective x OPC connector defective x Development power pack defective



311


C
Potential sensor calibration error 2





During drum potential sensor calibration, the drum potential sensor output voltage does not meet specification when test voltages (–100V, –800V) are applied to the drum.

x Potential sensor defective
x Potential sensor harness disconnected x Potential sensor connector defective or disconnected
x BCU defective x OPC connector defective
x Development power pack defective













SC No.

Symptom

Possible Cause


312


C
Potential sensor calibration error 3



During drum potential sensor calibration when adjusting the drum potential (VD), the drum potential sensor detects VD higher than VG (grid voltage).
-or-
When adjusting VD (drum surface potential of black areas after exposure), even after 5 adjustments of VG (charge corona grid potential), VD could not be set in the target range (–800r10 + VL + 130V)

x Potential sensor defective
x Potential sensor harness disconnected x Potential sensor connector defective or disconnected
x BCU defective x OPC connector defective x Development power pack defective x Charge corona unit worn out, dirty



314


C
Potential sensor calibration error 4



During drum potential sensor calibration when adjusting the drum potential (VH) for LD power adjustment, the first time the VH pattern is made, the drum potential sensor detects that VH is more than 500V:
VH > |–500 + VL + 130| V

x Potential sensor defective
x Potential sensor harness disconnected x Potential sensor connector defective or disconnected
x BCU defective x OPC connector defective x LD defective



315


C
Potential sensor calibration error 5



During drum potential sensor calibration, when –100V is applied to the drum, the output value is out of the prescribed range.

x Potential sensor defective
x Potential sensor harness disconnected x Potential sensor connector defective or disconnected
x BCU defective x OPC connector defective x Development power pack defective



316


C
Potential sensor calibration error 6



During drum potential sensor calibration, when –800V is applied to the drum, the output value is out of the prescribed range.

x Potential sensor defective
x Potential sensor harness disconnected x Potential sensor connector defective or disconnected
x BCU defective x OPC connector defective x Development power pack defective



317


C
Potential sensor calibration error 7



During drum potential sensor calibration, when VL is adjusted, the pattern surface potential VL pattern is not within range 0V ~ –400V. (VL is the potential after exposing a white pattern.)

x Potential sensor defective
x Potential sensor harness disconnected x Potential sensor connector defective or disconnected
x BCU defective x OPC connector defective
x Charge corona power pack defective x Development power pack defective



321


D
No laser writing signal (F-GATE) erro r 1



The laser writing signal (F-GATE) for the IPU does not go LOW within 60 s.

x IPU board defective
x PCI bus between controller board, IPU board defective








SC No.

Symptom

Possible Cause


322


D
Laser synchronization detector error





After the polygon motor reaches standard rotation speed and the LD unit fires for 500 ms, the laser synchronization detector does not generate a signal.

x Harness between detector and I/F disconnected or damaged
x Detector is installed incorrectly.
x Detector board is defective x Controller board defective x IPU board defective x LDB defective



335


D
Polygonal mirror motor error 1





The ready signal does not go low within 20 s after the polygonal mirror motor turns on or changes speed of rotation.

x Harness between I/F and polygon motor disconnected or defective
x Polygon motor or polygon motor driver defective x IPU board defective



336


D
Polygonal mirror motor error 2





The ready signal does not go high within 20 s after the polygonal mirror motor turns off.

x Harness between I/F and polygon motor disconnected or defective
x Polygon motor or polygon motor driver defective x IPU board defective



337


D
Polygonal mirror motor error 3





The XSCRDY signal goes high while the polygonal mirror motor turns on, even though there was no demand for either turning off the motor or changing the motor speed.

x Harness between the polygon motor and I/F disconnected or defective. x Polygon motor or polygon motor driver defective x IPU board defective



338


D
Polygonal mirror motor error 1





During exposure, while the polygon motor is rotating, the XSCRDY signal goes high.

x Harness between the polygon motor and I/F disconnected or defective. x Polygon motor or polygon motor driver defective x IPU board defective



340


D
TD sensor output error





TD sensor output voltage (Vt), measured during each copy cycle, is detected 10 times at one of the following levels: Vt = 0.5 volts or lower
Vt = 4.0 volts or higher

x TD sensor defective
x TD sensor harness disconnected x TD sensor connector disconnected or defective
x BCU defective x ریکو آفیشیو TONER ریکو آفیشیو 2051 bottle motor defective

Note: When the TD sensor is defective, the ریکو آفیشیو TONER ریکو آفیشیو 2051 supply is controlled using pixel count and the ID sensor.
























SC No.

Symptom

Possible Cause


341


C
TD sensor adjustment error 1





During the TD sensor auto adjustment, the TD sensor output voltage (Vt) is 2.5 volts or higher even though the control voltage is
set to the minimum value (PWM =
0)
When this error occurs, SP2-906-1 reads 0.00V.
Note: This SC is released only after correct adjustment of the TD sensor has been achieved. Switching the machine off and on will cancel the SC display, but does not release ID sensor ریکو آفیشیو TONER ریکو آفیشیو 2051 supply.

x TD sensor defective
x TD sensor harness disconnected x TD sensor connector disconnected or defective
x BCU defective x ریکو آفیشیو TONER ریکو آفیشیو 2051 bottle motor defective

Note: When the TD sensor is defective, the ریکو آفیشیو TONER ریکو آفیشیو 2051 supply is controlled using pixel count and the ID sensor.



342


C
TD sensor adjustment error 2





During the TD sensor auto adjustment, the TD sensor output voltage (Vt) does not enter the target range (3.0 ± 0.1V) within 20 s.
When this error occurs, the indication of SP2-906-1 reads 0.00V.
Note: This SC is released only after correct adjustment of the TD sensor has been achieved. Switching the machine off and on will cancel the SC display, but does not release ID sensor ریکو آفیشیو TONER ریکو آفیشیو 2051 supply.

x TD sensor defective
x TD sensor harness disconnected x TD sensor connector disconnected or defective x BCU defective



345


D
Development output abnormal





The high voltage applied to the development unit is detected 10 times higher than the upper limit (45%) of PWM.

x Development power pack defective x Development bias connection defective x Development bias connector disconnected or defective



350


C
ID sensor error 1





One of the following ID sensor output voltages was detected twice consecutively when checking the ID sensor pattern.
Vsp t 2.5V
Vsg < 2.5
Vsp = 0V
Vsg = 0

x ID sensor defective
x ID sensor harness disconnected x ID sensor connector defective
x BCU defective
x Defect at ID sensor pattern writing x Charge power pack defective x ID sensor dirty



351


C
ID sensor error 2





The ID sensor output voltage is 5.0V and the PWM signal input to the ID sensor is 0 when checking the ID sensor pattern.


x ID sensor defective
x ID sensor harness disconnected x ID sensor connector defective
x BCU defective
x Defect during ID sensor pattern writing x Charge power pack defective x ID sensor dirty







SC No.

Symptom

Possible Cause


352


C
ID sensor error 3





For 2 s during the ID sensor pattern check, the ID sensor pattern edge voltage is not 2.5V or the pattern edge is not detected within 800 ms.

x ID sensor defective
x ID sensor harness disconnected x ID sensor connector defective
x BCU defective
x Defect during ID sensor pattern writing x Charge power pack defective x ID sensor dirty



353


C
ID sensor error 4





One of the following ID sensor output voltages is detected at ID sensor initialization.
x Vsg < 4.0V when the maximum PWM input (255) is applied to the ID sensor.
x Vsg t 4.0V when the minimum PWM input (0) is applied to the ID sensor.

x ID sensor defective
x ID sensor harness disconnected x ID sensor connector defective
x BCU defective
x Defect during ID sensor pattern writing x Charge power pack defective x ID sensor dirty



354


C
ID sensor error 5





20 s after the start of automatic adjustment, Vsg cannot be adjusted to target (4.0 r 0.2V).


x ID sensor defective
x ID sensor harness disconnected x ID sensor connector defective
x BCU defective
x Defect during ID sensor pattern writing x Charge power pack defective x ID sensor dirty



355


C
ID sensor pattern voltage error





Drum potential sensor output is out of the target range (-100 - -400V) when reading the drum voltage for the ID sensor pattern.

x Drum potential sensor defective x Drum potential sensor harness disconnected
x Drum potential sensor connector defective
x IOB defective
x Defect during ID sensor pattern writing x Charge power pack defective x Charge corona wire dirty









SC400: Image Development System (2)



SC No.

Symptom

Possible Cause


401


D
Transfer output abnormal



When the transfer is output, the feedback voltage remains higher than 4V for 60 ms.

x Transfer power pack defective x Poor connection between the transfer current terminal and the transfer power pack



402

D

Transfer output abnormal release det ection



When the transfer is output, there is hardly any feedback voltage within 60 ms even with application of 24% PWM.

x Transfer power pack defective x Transfer unit harness disconnected x Transfer connector disconnected, defective



430

D

Quenching lamp error



At the completion of auto process control initialization, the potential of the drum surface detected by the potential sensor is more than – 400V, the prescribed value.

x Quenching lamp defective
x Quenching lamp harness disconnected x Quenching lamp connector disconnected or defective



440

D

Main motor lock



The main motor lock signal remains low for 2 seconds while the main motor is on.

x Too much load on the drive mechanism x Main motor defective



441

D

Development motor lock



The development motor lock signal remains high for 2 seconds while the development motor is on.

x Too much load on the drive mechanism x Development motor defective



490

D

Main fan abnormal



The main fan motor lock signal goes high for 5 s while the fan is on.

x Too much load on the motor, motor is blocked by something x Fan connector disconnected



495

D

ریکو آفیشیو TONER ریکو آفیشیو 2051 recycling unit error



Encoder pulse does not change for 3 s after the main motor switches on.

x Too much load on the drive mechanism x ریکو آفیشیو TONER ریکو آفیشیو 2051 end sensor detective, disconnected



496

D

ریکو آفیشیو TONER ریکو آفیشیو 2051 collection bottle error



The ریکو آفیشیو TONER ریکو آفیشیو 2051 collection bottle set switch remains off when the front door is closed.

x No ریکو آفیشیو TONER ریکو آفیشیو 2051 collection bottle set
x Poor connection on the switch connector



497

D

ریکو آفیشیو TONER ریکو آفیشیو 2051 collection motor error



The ریکو آفیشیو TONER ریکو آفیشیو 2051 collection motor connector set signal remains off for 1 s.

x ریکو آفیشیو TONER ریکو آفیشیو 2051 collection motor defective x Motor connector disconnected







SC No.

Symptom

Possible Cause


501


B
Tray 1 lift malfunction





x The lift sensor is not activated within 10 seconds after the tray lift motor starts lifting the bottom plate.
x Paper height sensor actuator does not move away from the sensor for 4 counts.

x Tray lift motor defective or disconnected x Paper or other obstacle trapped between tray and motor
x Pick-up solenoid disconnected or blocked by an obstacle



502


B
Tray 2 lift malfunction





x The lift sensor is not activated within 10 seconds after the tray lift motor starts lifting the bottom plate.
x Paper height sensor actuator does not move away from the sensor for 4 counts.

x Tray lift motor defective or disconnected x Paper or other obstacle trapped between tray and motor
x Pick-up solenoid disconnected or blocked by an obstacle



503


B
Tray 3 lift malfunction





x The lift sensor is not activated within 13 s after the tray lift motor starts lifting the bottom plate.
x At power on, or when the tray set sensor goes on after tray inserted, the tray continues to lower for 5 s. The motor stops but restarts when the tray is re-inserted.

x Tray lift motor defective or poor connection x Lift sensor defective or poor connection



504


B
Tray 4 lift malfunction





Japan only.





507


B
LCT feed motor malfunction





One of the following conditions is detected: x The LD signal from the feed motor is detected abnormal for 50 ms after the motor switches on.
x At power on, the motor is detected loose or disconnected.

x Feed motor defective
x Feed motor connector disconnected x Obstacle interfering with operation of motor



510


B
LCT tray malfunction





One of the following conditions is detected:
x When the bottom plate is lifted, the upper limit sensor does not come on for 18 s.
x When the bottom plate is lowered, the lower limit sensor does not come on for 18 s.
x After lift begins, the upper limit sensor does not switch on before the pick-up solenoid switches on.
x The paper end sensor switches on during lift and the upper limit sensor does not switch on for 2.5 s, and a message prompts user to reset paper.

x Tray lift motor defective or connector disconnected
x Lift sensor defective or disconnected x Pick-up solenoid defective or disconnected x Paper end sensor defective








SC500: Feed, Transport, Duplexing, and Fusing Systems



SC No.

Symptom

Possible Cause


515


B
Tandem rear fence motor error



One of the conditions is detected:
x The rear fence does not reach the return position within 10 s after the rear fence motor switches on, or does not return to the HP. x The HP sensor and return sensor switch on at the same time.

x Rear fence motor defective or poor connection
x Paper or other obstacle trapped between tray and motor
x Motor mechanical overload
x Return sensor or HP sensor defective or dirty



516


B
Tandem side fence motor error







The side fences do not reach the fully open or closed position within 2 seconds after the side fence motor switches on.

x Side fence motor defective or poor connection
x Motor mechanical overload
x Side fence positioning sensor defective or dirty



520


D
Duplex jogger motor error 1



When the jogger fence moves to the home position, the jogger HP sensor does not turn on even if the jogger fence motor has moved the jogger fence 153.5 mm.

x Paper or other obstacle has jammed mechanism
x Sensor connector disconnected or defective x Sensor defective



521


D
Duplex jogger motor error 2



When the jogger fence moves from the home position, the jogger fence HP sensor does not turn off even if the jogger motor has moved the jogger fence 153.5 mm.

x Paper or other obstacle has jammed mechanism
x Sensor connector disconnected or defective x Sensor defective



541


A
Fusing thermistor open



x The fusing temperature detected by the thermistor is below 7qC for 35 seconds. x The center thermistor (noncontact) abnormal.

x Thermistor open
x Thermistor connector defective x Thermistor damaged or warped x Fusing temperature –15% less than the standard input voltage



542


A
Fusing temperature warm-up error



x After power on, or after closing the front door, the hot roller does not reach the 80qC control temperature within 360 s. x After the fusing lamp temperature exceeds 80qC, temperature does not change 2 degrees within 20 s.

x Fusing lamp disconnected
x Thermistor warped or installed incorrectly x Thermostat operating



543


A
Fusing lamp overheat error 1 (softwa re)



x Central thermistor detected a temperature of 230qC at the center of the hot roller.
x End thermistor detected 220qC x 100 ms 5 times at the end of the hot roller.

x PSU defective x BCU defective



544


A
Fusing lamp overheat error 1 (hardw are)



The BCU detects an overheat error even if the protection in the software does not work.


x PSU defective x BCU defective






SC No.

Symptom

Possible Cause


545


A
Fusing lamp overheat error 2



After hot roller reaches the warmup temperature, the fusing lamps continued full capacity output for 55 s without the hot roller rotating (for a total of 45s).

x Fusing thermistor out of position



547


D
Zero cross signal malfunction



One of the following conditions is detected 10 times: x When the main switch is on, the frequency measured by the number of zero cross signals for 500 ms is larger than 66Hz or smaller than 45 Hz. x The interval between one zero cross signal and the next is 7.5 ms or shorter 3 times consecutively for 500 ms.

x Noise on the ac power line



550


A
Fusing Web End



Web end detected 5 times within 500 ms and web motor continues to rotate 40 s. If web end is detected for another 400 ms, then the SC is logged.

x Web end (requires replacement) x Web end sensor defective

Note: After replacing the web with a new one, reset SP1902 001 to 0 to release SC550.



590


D
ریکو آفیشیو TONER ریکو آفیشیو 2051 collection motor error



The ریکو آفیشیو TONER ریکو آفیشیو 2051 collection motor sensor output does not change for 3 seconds while the ریکو آفیشیو TONER ریکو آفیشیو 2051 collection motor is on.

x ریکو آفیشیو TONER ریکو آفیشیو 2051 collection motor defective x Motor drive defective
x ریکو آفیشیو TONER ریکو آفیشیو 2051 collection motor sensor connector defective x Motor overload



599


D
1-bin Exit Motor Error (should only occur in Japanese models)



The transport lock sensor output does not change within 300 ms after the motor switches on.

x Motor overload x Motor drive defective









SC600: Data Communication



SC No.

Symptom

Possible Cause


601


D
Communication error between BCU and scanner unit



x BCU does not communicate with scanner unit within 0.8 s after power on. x BCU does not detect a break signal after connecting to scanner unit.
x Communication error detected 3 times.

x Serial line connection unstable x External noise on the line



610


D
BCU ļ ADF communication/timeout abnormal



After 1 data frame is sent to the ADF, an ACK signal is not received within 100 ms, and is not received after 3 retries.

x Serial line connection unstable x External noise on the line



611


D
BCU ļ ADF communication/break r eception abnormal



During communication a break (Low) signal was received from the ADF.

x Serial line connection unstable x Harness disconnected or defective



612


D
BCU ļ ADF communication/comma nd abnormal



An command that cannot be executed was sent from the main machine to the ADF.

x A software error, result of an abnormal procedure.



620


D
BCU ļ ADF communication/timeout error



After 1 data frame is sent to the finisher MBX, an ACK signal is not received within 100 ms, and is not received after 3 retries.

x Serial line connection unstable x External noise on the line



621

D

BCU ļ Finisher communication/bre ak error



During communication with the finisher MBX, the BCU received a break (Low) signal from the finisher.

x Serial line connection unstable x External noise on the line



623

D

BCU ļ Tray 1~3 communication/tim eout error



After 1 data frame is sent to the trays, an ACK signal is not received within 100 ms, and is not received after 3 retries.

x Serial line connection unstable x External noise on the line



624

D

BCU ļ Tray 1~3 communication/bre ak reception error



During communication with the finisher trays, the BCU received a break (Low) signal.

x Serial line connection unstable x External noise on the line



626

D

BCU ļ LCT communication/timeout error



After 1 data frame is sent to the LCT, an ACK signal is not received within 100 ms, and is not received after 3 retries.

x Serial line connection unstable x External noise on the line



627

D

BCU ļ LCT communication/break r eception error



During communication with the LCT, the BCU received a break (Low) signal.

x Serial line connection unstable x External noise on the line



630

D

CSS (RSS) communication error bet ween line adapter and CSS center



Japan only









SC No.

Symptom

Possible Cause


632


B
Key/card counter device error 1



After 1 data frame is sent to the device, an ACK signal is not received within 100 ms, and is not received after 3 retries.

x The serial line from the device to the ریکو آفیشیو ریکو آفیشیو 2051 is unstable, disconnected, or defective.



633


B
Key/card counter device error 2



During communication with the device, the BCU received a break (Low) signal.

x The serial line from the device to the ریکو آفیشیو ریکو آفیشیو 2051 is unstable, disconnected, or defective.



634


B
Key/card counter device error 3



After installation of the device, a message alerts user to a backup RAM error.

x Device control board defective x Device control board backup battery defective



635


B
Key/card counter device error 4



After installation of the device a message alerts user to a battery voltage abnormal error.

x Device control board defective x Device control board backup battery defective



640


C
BCU ļ Controller data transfer error 1



Data is sent from the BCU to the controller, but the transmission causes a checksum error.

x The error is logged but the machine can continue to operate.



641


C
BCU ļ Controller data transfer error 2



Data is sent from the BCU to the controller, but the transmission causes a frame error.

x The error is logged but the machine can continue to operate.



670

D

Engine startup error



x Engine does not respond within 30 s after power on.
x Engine down detected suddenly during power on and warmup.

x BCU installation incorrect x BCU defective
x Sudden communication reset occurred between the BCU and the controller.



672

D

Controller startup error



x After power on the line between the controller and the operation panel does not open for normal operation.
x After normal startup, communication with the controller ceases.

x Controller stalled
x Controller installed incorrectly x Controller board defective
x Operation panel harness disconnected or defective
x The optional fax unit was installed with the jumper on the MBU at the OFF position. The jumper must be removed and set at the ON position.



690

D

GAVD Block 12 bus error



The register for this block is set for an error.

x IPU defective



691

D

GAVD FCI Block I2 bus error



The register for this block is set for an error.

x IPU defective



692

D

CDIC GAVD Block I2 bus error



The register for this block is set for an error.

x IPU defective









SC700: Peripherals



SC No.

Symptom

Possible Cause


700


D
ADF original pick-up error 1





Pick-up roller HP sensor signal does not change after the pick-up motor has turned on.

x Pick-up roller HP sensor defective x Pick-up motor defective
x Timing belt slipping, out of position x ADF main board defective



701

D

ADF bottom plate motor error





x Bottom plate position sensor does not detect the plate after the bottom plate lift motor switches on to lift the plate.
x Bottom plate HP sensor does not detect the plate after the bottom plate motor reverses to lower the plate.

x Bottom plate position sensor defective x Bottom plate HP sensor defective x Bottom plate motor defective x ADF main board defective



720

D

Finisher transport motor error





The encoder pulse of the transport motor does not change state (high/low) within 600 ms and does not change after 2 retries.

x Finisher transport motor defective x Transport motor harness disconnected, or defective x Finisher main board defective



722


B
Finisher jogger motor error





x The finisher jogger HP sensor remains de-activated for more 1,000 pulses when returning to home position. x The finisher jogger HP sensor remains activated for more than 1,000 pulses when moving away from home position.

x Jogger HP sensor defective x Jogger mechanism overload x Jogger motor defective (not rotating) x Finisher main board defective x Harness disconnected or defective



724


B
Finisher staple hammer motor error





Stapling does not finish within 450 ms after the staple hammer motor switches on and the stapler jams. Stapler is released from the reverse lock status. If the stapler does not operate within 450 ms, even in the reverse lock position, then the SC is logged.

x Staple jam
x Stapler operation overload x Staple hammer motor defective x Motor connector disconnected, or defective



725


B
Finisher stack feed-out motor error





The stack feed-out belt HP sensor does not activate within the prescribed number of pulses after the stack feed-out motor turns on and does not activate after 2 retries.

x Stack feed-out HP sensor defective x Harness disconnected or defective x Stack feed-out motor defective x Finisher main board defective x Motor overload



726


B
Finisher upper tray lift motor error





The paper height sensor does not activate within the prescribed time after the upper tray lift motor turns on, or the sensor remains on after the motor reverses to lower the tray.

x Upper tray paper height sensor defective x Sensor harness disconnected, defective x Tray lift motor defective x Finisher main board defective x Tray lift motor overload









SC No.

Symptom

Possible Cause


727


B
Finisher stapler rotation motor error



The stapler motor switches on but the motor does not return to the home position within the prescribed number of pulses. After 2 counts, the SC is logged as a jam.

x Stapler rotation motor defective x Poor stapler rotation motor connection x Stapler rotation sensor defective x Finisher main board defective x Rotation motor overload



729


D
Finisher punch motor error



The punch HP sensor does not activate within the prescribed time the punch motor turns on.

x Punch HP sensor defective
x Sensor harness disconnected, defective x Punch motor defective x Finisher main board defective x Poor punch motor overload



730


B
Finisher stapler movement motor err or



The stapler HP sensor does activate within the prescribed time after the stapler motor turns on and moves the stapler away from home position. After 2 counts, the SC is logged as a jam.

x Stapler HP sensor defective
x Sensor harness disconnected, defective x Stapler movement motor defective x Finisher main board defective x Stapler movement motor overload



732


B
Finisher shift roller motor error



The shift roller HP sensor does not activate within the prescribed time after the shift roller motor turns on. After 2 counts, the SC is logged as a jam.

x Shift roller HP sensor defective x Sensor harness disconnected, defective x Shift roller motor defective x Finisher main board defective x Shift roller motor overload



733


D
Finisher lower tray lift motor error



After the lift motor switches on to lift the tray, paper height sensor 2 does not detect the top of the paper stack, or after the motor reverses to lower the stack the top of the stack remains detected (the status of paper height sensor 1 does not change). After 2 counts, the SC is logged as a jam.

x Paper height sensor 1 or 2 defective x Sensor harness disconnected, defective x Tray lift motor defective x Finisher main board defective x Tray lift motor overload



735


B
Finisher pre-stack motor error



x The pre-stack motor starts but does not return to the home position within 400 pulses. After 2 counts, the SC is logged as a jam.
x Motor does not return to the home position within 280 pulses immediately before or after prestacking. After 2 counts, the SC is logged as a jam.

x Jogger HP sensor defective x Sensor harnesses disconnected, defective
x Pre-stack motor defective x Finisher main board defective x Pre-stack motor overload



736


B
Finisher paper exit guide plate motor error



The paper exit guide plate motor starts but the paper exit guide plate HP sensor does not activate within 750 ms. After 2 counts, the SC is logged as a jam.

x Guide plate HP sensor defective x Sensor harness disconnected, defective x Paper exit guide plate motor defective x Finisher main board defective x Guide plate motor overload.














SC No.

Symptom

Possible Cause


737


B
Trimmed staple waste hopper full



The hopper that holds the waste from staple trimming is full.

x Staple waste hopper full x Staple waste sensor defective



738


B
Finisher pressure plate motor error



The pressure plate motor switches on but does not return to the home position within the prescribed time after 2 counts.

x HP sensor defective
x Harness disconnected, defective x Motor defective
x Finisher main board defective x Motor overload



739


B
Finisher folder plate motor error



The folder plate motor turns on but the plate does not return to the home position within the prescribed time for 2 counts.

x Plate HP sensor defective x Harness disconnected, defective x Folder plate motor defective x Finisher main board defective x Folder plate motor overload



740


B
Finisher front saddle-stitch stapler m otor error



Saddle-stitch stapler motor fails to operate within 450 ms within 2 counts..

x HP sensor defective
x Harness disconnected, defective x Stapler motor defective x Finisher main board defective x Stapler motor overload



741


B
Finisher rear saddle-stitch stapler m otor error



Saddle-stitch stapler motor fails to operate within 450 ms within 2 counts..

x HP sensor defective
x Harness disconnected, defective x Stapler motor defective x Finisher main board defective x Stapler motor overload



742


B
Finisher jogger side fence motor erro r



The jogger motor turns on but the side fences to not return to the home position within 340 pulses for 2 counts.

x HP sensors defective
x Harness disconnected, defective x Motor defective
x Finisher main board defective x Motor overload



743


B
Finisher Jogger Motor Error



The jogger fences did not return to their horizontal home positions on both ends of the unit, or to their down home positions within the prescribed number of pulses. Only staple mode is disabled. Shift output, or output to the proof tray can still be used.

x Jogger lift sensor or jogger fence sensor connectors disconnected, loose, or damaged.
x Jogger lift sensor or jogger fence sensor is defective.
x Main harness connection loose or broken.
x Shift jogger motor or shift jogger lift motor defective.
Finisher main board defective.



750


B
Cover interposer bottom plate motor error



x The bottom plate motor turns on to raise the bottom plate but the plate position sensor does not detect the plate within 3 s.
x The bottom plate motor reverses to lower the bottom plate but the bottom plate HP sensor does not detect the plate within 3 s.

x Bottom plate position sensor defective x Bottom plate HP sensor defective x Bottom plate motor defective
x Cover sheet feeder main board defective x Harnesses disconnected, defective






SC No.

Symptom

Possible Cause


800


D
Video output transfer does not end ( K)



Video signal is sent to the engine but no command is received within the prescribed time from the engine to signal the end of transfer – output all black.

x Controller board defective



804


D
Video input transfer does not end (K)



Video transfer is requested from the scanner, but no command is received within the prescribed time from the scanner to signal a response – output all black.

x Controller board defective



818


C
Watchdog error



Control error

x System program defective x Controller board defective x Optional board defective



819

C

Fatal kernel error



Software defective

x Software defective



820

C

Self-diagnostic error: CPU



Unexpected external error or interrupt occurred.

x Controller board defective x Software defective



821

C

Self-diagnostic error: ASIC



ASIC timer interrupt and CPU timer interrupt are compared and found to be out of range.

x Controller board defective



822

C

Self-diagnostic error: HDD



Check performed when HDD is installed: x HDD device busy for over 31 s.
x After a diagnostic command is set for the HDD, but the device remains busy for over 6 s.
x A diagnostic command is issued to the HDD device but the result is an error.

x HDD defective
x HDD harness disconnected, defective x Controller board defective



823

C

Self-diagnostic error: NIB



x The SUM of the MAC address written in the SEEP ROM for the MAC address is calculated and compared with the stored SUM and judged NG.
x There is a format error in the MAC address stored in the SEEP ROM for the MAC address.
x A loopback error occurs on the PHY chip of the NIB.

x NIB board defective x Controller board defective



824


C
Self-diagnostic error: NVRAM



NVRAM device does not exist, or NVRAM device is damaged.

x NVRAM defective x Controller board defective



825


C
Self-diagnostic error: NVRAM (option )



Optional NVRAM is installed, but a write/verify error occurred.

x Incorrect NVRAM installed.








SC800: Overall System



SC No.

Symptom

Possible Cause


826


C
Self-diagnostic error: NVRAM (option NVRAM)



The difference between the 1 s measured for RTC in the NVRAM and the 1 s timeout of the CPU is out of range, or the NVRAM is not detected.

x NVRAM defective x NVRAM installed incorrectly



827

C

Self-diagnostic error: RAM



The write/verify check for the RAM mounted on the board resulted in an error.

x Controller board defective x RAM defective



828

C

Self-diagnostic error: ROM



x Measuring the CRC for the boot monitor and operating system program results in an error.
x A check of the CRC value for ROMFS of the entire ROM area results in an error.

x Software defective x Controller board defective x ROM defective



829

C

Self-diagnostic error: RAM (option)



x A write/verify check of the RAM mounted on the board results in a error.
x The SPD value of the entire RAM DIM is incorrect, or cannot be read.

Note: RAM is not in use so the result is not displayed on the operation panel.

x Controller board defective x RAM defective



835

C

Self-diagnostic error: Centronic devic e



x Loopback connector is connected but check results in an error.
x Loopback connector is connected but DMA data error detected.
x Centronic loopback connector is not connected for detailed selfdiagnostic test.

x Controller board defective x Centronic loopback connector not connected correctly x Centronic loopback connector defective



836

C

Self-diagnostic error: Font ROM



A device exists in the font area but it contains corrupted data.

x Font device defective



837

C

Self-diagnostic error: Font ROM (opti on)



A device exists in the font area but it contains corrupted data.

x Font device defective



838

C

Self-diagnostic error: Clock Generato r



Setup data is read from the clock generator via the I2C bus but differs from the prescribed value.

x Controller board defective



850


B
Net I/F error



x Duplicate IP addresses. x Illegal IP address.
x Driver unstable and cannot be used on the network.

x IP address setting incorrect x NIB (PHY) board defective
x Controller board defective








SC No.

Symptom

Possible Cause


851


B
IEEE 1394 I/F error



Driver setting incorrect and cannot be used by the 1394 I/F.

x 1394 I/F connection incorrect x 1394 I/F board defective x Controller board defective



USB driver is corrupted or has become unstable and cannot be used by the USB I/F.

x USB connection incorrect x Controller board defective



860


B
HDD startup error at main power on



x HDD is connected but a driver error is detected.
x The driver does not respond with the status of the HDD within 30 s.

x HDD is not initialized x Level data is corrupted x HDD is defective



861


B
HDD re-try failure



At power on with the HDD detected, power supply to the HDD is interrupted, after the HDD is awakened from the sleep mode, the HDD is not ready within 30 s.

x Harness between HDD and board disconnected, defective
x HDD power connector disconnected x HDD defective
x Controller board defective



862


A
Number of bad sectors exceeds allo wed maximum



The number of bad sectors on the HDD in the area for storing images exceeds 101.

x Execute 5832 001 to format the HDD and replace the bad sectors. HDD replacement is recommended because an HDD unit that generates bad sectors is probably of poor quality and performs poorly.



863


D
HDD data read failure



The data written to the HDD cannot be read normally, due to bad sectors generated during operation.

x HDD defective
x Note: If the bad sectors are generated at the image partition, the bad sector information is written to NVRAM, and the next time the HDD is accessed, these bad sectors will not be accessed for read/write operation.



864


D
HDD data CRC error



During HDD operation, the HDD cannot respond to an CRC error query.

x Data transfer did not execute normally while data was being written to the HDD.



865


D
HDD access error



HDD responded to an error during operation for a condition other than those for SC863, 864.

x HDD defective.









SC900: Miscellaneous



SC No.

Symptom

Possible Cause


900


D
Electrical total counter error



The total counter contains something that is not a number.

x NVRAM defective



901


D
Mechanical total counter error



The mechanical counter is not connected.

x Mechanical total counter defective x Mechanical total counter connector not connected



951


C
F-GATE signal error



When the IPU has already received the F-GATE signal (laser writing start trigger signal), the IPU receives another F-GATE signal.

x Software defective x BCU defective



953

D

Scanner image setting error



The settings required for image processing using the scanner are not sent from the IPU.

x Software defective



954

D

Printer image setting error



The settings required for image processing using the printer controller are not sent from the IPU.

x Software defective



955

D

Memory setting error



The settings that are required for image processing using the memory are not sent from the IPU.

x Software defective



964

D

Printer ready error



The print ready signal is not generated for more than 17 seconds after the IPU received the print start signal.

x Software defective



984

D

Print image data transfer error



After a data transfer begins from the controller to the engine via the PCI bus, the transfer does not end within 15 s.

x Controller board defective
x BICU defective
x BICU, controller disconnected



985

D

Scanned image data transmission er ror



After a data transfer begins from the engine to the controller via the PCI bus, the transfer does not end within 3 s.

x Controller board defective
x BICU defective
x BICU, controller disconnected



986

D

Value of setting for software write pa rameter incorrect



The write parameter received by the write module at the beginning of the setting table is NULL.

x Controller board defective
x BICU defective
x BICU, controller disconnected



990

D

Software performance error



The software performs an unexpected function and the program cannot continue.

x Software defective, re-boot*1











SC No.

Symptom

Possible Cause


991


C
Software capable of looping cannot c ontinue



The software performs an unexpected function and the program cannot continue. However, unlike SC990, recovery processing allows the program to continue.

x Software defective, re-boot*1




*1: In order to get more details about SC990 and SC991:
1) Execute SP7403 or print an SMC Report (SP5990) to read the history of the 10 most recent logged errors.





2) If you press the zero key on the operation panel with the SP selection menu displayed, you will see detailed information about the recently logged SC990 or SC991, including the software file name, line number, and so on. 1) is the recommended method, because another SC could write over the information for the previous SC.





SC No.

Symptom

Possible Cause


992


C
Undefined software error





Software encountered an unexpected operation. This error is issued if the error cannot be covered by SC990.

x Software defective
x An error undetectable by any other SC code occurred



997


D
Cannot select application function





Application does not start after pressing the appropriate key on the operation panel.

x Software bug
x A RAM or DIMM option required by the application is not installed or not installed correctly.



998

D

Application cannot start





Register processing does not execute for any application within 60 s after the machine is powered on. All applications do not start correctly, and all end abnormally.

x Software bug
x A RAM or DIMM option required by the application is not installed or not installed correctly.



999

D

Program download error





The program download from the IC card does not execute normally.
This SC is not logged.

x Card installed incorrectly x BICU defective x IC card defective x NVRAM defective x Power down during program downloading




4.2.3 ADDITIONAL SC CODES PRINTED IN SMC REPORT
Here is a list of SC codes that are printed in the SMC report but may not appear in the operation panel display. Note that the codes that have the same number are identified by an additional 4-digit hexadecimal number.




SC No.

Symptom

Possible Cause


820

0001

TLB conversion (store) exception error

Unexpected error in CPU device: x Controller board defective x Boot monitor or self-diagnostic program corrupted



820

0002

TLB miss (load) exception error



820

0003

TLB miss (store) exception error



820

0004

Read address exception error



820

0005

Write address exception error



820

0006

Command bus exception error



820

0007

Data bus exception error



820

0008

System call exception error



820

0009

Break exception error



820

000A

Illegal command exception error



820

000B

Potential sensor exception error



820

000C

Overflow exception error



820

000D

UTLB miss exception error



820

0010

Allocation 0 error



820

0011

Allocation 1 error



820

0012

Allocation 2 error



820

0013

Allocation 3 error



820

0014

Allocation 4 error



820

0015

Allocation 5 error



820

00FF

Non-initialization allocation error

x CPU defective x Local bus defective x Controller board defective



820

0601

Read address exception error

x CPU device error x Controller board defective



820

0602

Write address exception error



820

0605

System call exception error



820

0606

Break point exception error



820

0607

Illegal command exception error



820

060A

Allocation 0 mask exception error

x CPU device error x ASIC device error x Controller board defective



820

060B

Allocation 1 mask exception error



820

060C

Allocation 2 mask exception error



820

060D

Allocation 3 mask exception error



820

060E

Allocation 4 mask exception error



820

0610

CPU timer 2 allocation set error

x CPU device error x Controller board defective



820

0612

ASIC allocation error

x ASIC device error x Controller board defective x Peripheral device defective



820

06FF

CPU master clock error

x CPU device error
x Error in CPU initialization data (ASIC error) x Controller board defective






SC No.

Symptom

Possible Cause


820

0702

Command cache error

x CPU cache defective x Controller board defective x Memory error (insufficient speed)



820

0709

Data cache error

x CPU device error
x Boot mode setting for CPU error x Controller defective x Insufficient memory



820

070A

Data cache clear error



820

0801

TLB virtual address error

x CPU device defective (controller board defective)



820

0804

TLB global error



820

0807

UTLB miss error



820

0808

TLB read miss error



820

0809

TLB write miss error



820

080A

TLB mode file error



820

4002

Single-precision calculation error

x CPU error (controller board defective)



820

4003

Double-precision calculation error



820

4004

Exception error



820

4005

Exception mask error



822

3003

HDD timeout

x HDD defective
x HDD connector disconnected, defective x ASIC device error (controller board defective)



822

3004

Self-diagnostic command error

x HDD defective



823

6101

MAC address SUM error

x NIB (PHY) board defective x Controller board defective



823

6104

PHY chip ID illegal



823

6105

PHY loopback error



824

1401

NVRAM verify error

x NVRAM defective



826

1501

Clock error

x Optional NVRAM defective



826

15FF

RTC non-detection error

x Incompatible NVRAM installed x NVRAM battery defective



826

0201

Resident memory verify error

x Memory on controller board defective x RAM DIMM defective



828

0101

Boost trap code (CODE) error

x Software storage error (re-install software) x Controller board defective



828

0104

ROM FS error

x ROM device error



828

0105

Forgery prevention error

x Forgery prevention chip defective x Forgery prevention chip error
x Replace the controller, ROM, or RAM DIMM



829

0301

Option memory 0 verify error

x Controller board internal memory error x RAM DIMM defective



829

0302

Option memory 0 configuration information error



835

1102

Verify error

x Loopback connector error (controller board defective)



835

110C

DMA verify error

x Loopback connector error x Controller board defective



835

1120

Loopback connector nondetection

x Loopback connector not set x Loopback connector error x Controller board defective



836

1601

Font ROM 0 error



837

1602

Font ROM 1 error



838

2701

Verify error












SC No.

Symptom

Possible Cause



853
D

IEEE802 11b card startup error



Not used.






854
D

IEEE802 11b card access error



Not used.






855
D

IEEE802 11b card error



Not used.






856
D

IEEE802 11b card connection board e rror



Not used.






870
B

Address book data error



The address book in the hard disk is accessed. o An error is detected in the address book data; address book data is not read; or data is not written into the address book.
NOTE: To recover from the error, do any of the following countermeasures:
Format the address book by using SP5-832-008 (all data in the address book–including the user codes and counters–is initialized)
Initialize the user data by using SP5832-006 and -007 (the user codes and counters are recovered when the main switch is turned on). Replace the hard disk (the user codes and counters are recovered when the main switch is turned on).

x Data corruption x Defective hard disk
x Defective software




920

D

Printer error



The printer program cannot be continued.

x Defective hardware x Data corruption x Defective software



925

D

Net file error



The management file for net files is corrupted; net files are not normally read.
Netfiles: Jobs to be printed from the document server using a PC and the DeskTopBinder software

x Defective hardware x Data corruption x Defective software



992

C

Other system SCs



The controller received an unknown SC code from the engine.

x Contact your product specialist.



993

D

Network error



The ASIC program of GW controller cannot be continued.

x Defective ASIC x Defective GW controller





4.3 B140/B246 SERIES SERVICE MODE 4.3.1 SERVICE MODE LOCK/UNLOCK
At locations where the machine contains sensitive data, the customer engineer cannot operate the machine until the Administrator turns the service mode lock off. This function makes sure that work on the machine is always done with the permission of the Administrator.
NOTE: This function is not used on B064 series machines.


If you cannot go into the SP mode, ask the Administrator to log in with the User Tool and then set “Service Mode Lock” to OFF. After he or she logs in: User Tools > System Settings > Administrator Tools > Service Mode Lock > OFF

x This unlocks the machine and lets you get access to all the SP codes.





x The CE can do servicing on the machine and turn the machine off and on. It is not necessary to ask the Administrator to log in again each time the machine is turned on.


If you must use the printer bit switches, go into the SP mode and set SP 5169 to “1”.
After machine servicing is completed: x Change SP 5169 from “1” to “0”. x Turn the machine off and on. Tell the administrator that you completed servicing the machine.

x The Administrator will then set the “Service Mode Lock” to ON.

4.3.2 B140/B246 SERIES SERVICE CALL CONDITIONS
There are 4 levels of service call conditions.


Level


Definition

Reset Procedure



A
Fusing unit SCs displayed on the operation panel. The machine is disabled. The user cannot reset the SC.

Enter SP mode, then turn the main power switch off and on.




B
SCs that disable only the features that use the defective item. Although these SCs are not shown to the user under normal conditions, they are displayed on the operation panel only when the defective feature is selected.

Turn the main power switch off and on.




C
SCs that are not shown on the operation panel. They are internally logged.

Logging only




D
Turning the operation switch or main power switch off then on resets SCs Displayed on the operation panel. These are re-displayed if the error occurs again.

Turn the operation switch or main power switch off and on.




4.3.3 B140/B246 SERIES SC CODE DESCRIPTIONS
Important
x If a problem concerns electrical circuit boards, always disconnect then reconnect
the connectors before replacing the PCBs. x If a motor lock error occurs, first check the mechanical load before replacing motors or sensors. x When a Level “A” or “B” SC occurs while in an SP mode, the display does not display the SC number. If this occurs, check the SC number after leaving the SP mode.
How to Read These Tables
Most of the SC codes in these tables apply to both the B140 Series and B246 Series machines. However, there are some differences. These differences are annotated: x If an SC code applies to the B140 Series machine only, this SC will be marked "B140" to the right of the number. x If an SC code applies to the B246 Series machine only, this SC will be marked "B246".
x If there is neither a "B140" nor "B246" notation, the SC code applies to both





machines. x Pay special attention to the "B140/B246 Duplicated Number" notation. The same number SC codes exists in both machines but the meaning is different.
SC100: Scanning System



SC No.

Symptom

Possible Cause


101


D
Exposure Lamp Error





At trigger on, the lamp was not detected on.

x Exposure lamp defective x Lamp regulator defective x Lamp regulator harness damaged, disconnected
x Dirty standard white plate
x Scanner mirror dirty or out of position x Lens dirty, out of position x SBU board defective



120


D
Scanner home position error 1





The scanner HP sensor does not detect the on condition during initialization or copying.

x BCU, SDRB (Scanner Driver Board) defective
x Scanner motor defective
x Harness between BCU, SDRB, scanner motor disconnected.
x Scanner HP sensor defective. x Harness between scanner HP sensor and BCU disconnected.
x Scanner wire, timing belt, pulley, carriage installed incorrectly.



121


D
Scanner home position error 2





The scanner HP sensor does not detect the off condition during initialization or copying.

x BCU, SDRB (Scanner Driver Board) defective
x Scanner motor defective
x Harness between BCU, SDRB, scanner motor disconnected
x Scanner HP sensor defective x Harness between scanner HP sensor and BCU disconnected
x Scanner wire, timing belt, pulley, carriage installed incorrectly.



122


D
Scanner home position error 3





The scanner home position sensor does not detect the on condition during original scanning.

x BCU, SDRB (Scanner Driver Board) defective
x Scanner motor defective
x Harness between BCU, SDRB, scanner motor disconnected
x Scanner HP sensor defective x Harness between scanner HP sensor and BCU disconnected
x Scanner wire, timing belt, pulley, carriage installed incorrectly






123


D
Scanner home position error 4





The scanner home position sensor does not detect the off condition during original scanning.

x BCU, SDRB (Scanner Driver Board) defective
x Scanner motor defective
x Harness between BCU, SDRB, scanner motor disconnected
x Scanner HP sensor defective x Harness between scanner HP sensor and BCU disconnected
x Scanner wire, timing belt, pulley, carriage installed incorrectly.



143


C
SBU auto adjust error





Automatic adjustment of the SBU fails when the machine is switched on.

x Exposure lamp defective x Exposure lamp regulator defective x Harness between exposure lamp and lamp regulator is disconnected
x White plate installed incorrectly or is dirty x Scanning mirrors of the exposure unit are dirty or out of position
x SBU board defective x VIB board defective.
x Harness between SBU, VIB disconnected
x Harness between VIB, BCU disconnected



144


D
SBU transmission error





After the SBU switches on, the BCU detects one of the following conditions on the SBU: x 1 s after power on, the SYDI signal does not go high, even after 1 retry.
x 1 s after power on, the SYDI signal goes high, but the SBU ID could not be read after 3 attempts.

x SBU defective x VIB defective
x Harness (40-pin shielded) between the
SBU, VIB is disconnected x Harness (shielded cable) between the
VIB, BCU is disconnected



165



Copy data security unit error B828

B246







The copy data security option is installed by not operating correctly.

x Copy data security card corrupted x The board is not installed or the board is defective x IPU board defective











181


D
CIS lamp abnormal





After the CIS lamp trigger goes on, the CIS lamp is not detected on. Detecting the lamp on or off determines the peak white level value for shading correction. (If the peak level is determined to be below a certain level, the CIS lamp is judged to be off.)

x CIS lamp defective
x CIS power supply board defective x CIS lamp regulator defective x Harness between lamp and lamp regulator is disconnected.
x Harness between CIS, ADF is disconnected
x CIS exposure glass dirty.
x White roller dirty or installed incorrectly x CIS unit defective



183


C
CIS auto adjust error





Automatic adjustment of the CIS unit failed.

x CIS unit defective x CIS exposure glass dirty
x White roller dirty or installed incorrectly



184


D
CIS transmission error





When the CIS is powered on, the ADF detects one of the following abnormal conditions on the CIS unit:
x The SOUT signal does not go high within 1 s after power on.
x The SOUT signal goes high within 1 s after power on, but the SBU ID cannot be read after 3 attempts.

x CIS unit defective
x Harness between the CIS, ADF is disconnected









SC200: Exposure


202



Polygon mirror motor error 1: Timeout at ON

B246



The polygon mirror motor unit did not enter "Ready" status within 20 sec. after the motor was turned on, or within 20 sec. after the speed of rotation was changed.

x The polygon mirror motor PCB connector is loose, broken, or defective
x Polygon mirror motor PCB defective x Polygon mirror motor defective x IPU defective



203



Polygon mirror motor error 2: Timeou t at OFF

B246



The polygon mirror motor did not leave "Ready" within 3 sec. after the motor was switched off. (The XSCRDY signal did not go HIGH
(inactive) within 3 sec.)

x The polygon mirror motor PCB connector is loose, broken, or defective
x Polygon mirror motor PCB defective x Polygon mirror motor defective x IPU defective



204



Polygon mirror motor error 3: XSCR DY signal error

B246



The polygon mirror motor "Ready" signal went inactive (HIGH) while the motor was operating at normal speed, even though the motor was neither switched off nor was there a request for a change in speed.

x Electrical oise interference on the line with the motor signals
x Polygon mirror motor PCB connector loose, broken, defective
x Polygon mirror motor PCB defective x Polygon mirror motor defective



205



Polygon mirror motor error 4: Unstab le timeout

B246



The "Ready" signal (XSCRDY) was detected as unstable for more than 20 sec. while the polygon mirror motor was operating at normal speed.

x Electrical noise on the line with the motor signals
x Polygon mirror motor PCB connector loose, broken, defective
x Polygon mirror motor PCB defective x IPU defective



220



Laser synchronization detection error

B246



The 1st laser synchronization detection unit could not detect the line synchronization signal (DETP0) within 500 ms while the polygon mirror motor was operating at normal speed.
Note: The unit polls for the signal every 50 ms. This SC is issued after the 10th attempt fails to detect the signal.

x Laser synchronization board connector loose, broken, defective
x Laser synchronization detection board is not installed correctly (out of alignment)
x Laser synchronization board defective x IPU defective












SC300: Image Development System (1)



SC No.

Symptom

Possible Cause


300


D
Charge corona output error





The feedback voltage from the charge corona unit is detected too high 9 times.

x Charge corona power pack defective x Charge corona harness disconnected x Poor charge corona unit connection



303


C
Charge corona grid leak





When the high voltage is output to the corona grid, feedback voltage exceeds the prescribed value 9 times.

x Charge corona power pack defective x Charge corona harness disconnected x Poor charge corona unit connection



304


D
Charge grid circuit open





When high voltage goes to the corona grid, feedback voltage is more than the set value 9 times. This feedback voltage is used to update PWM for output control.

x Charge corona unit defective or disconnected
x Charge corona harness defective x Charge corona power pack is defective.



305


D
Charge corona wire cleaner error 1





The charge cleaner pad does not arrive at the home position:
x Motor locked within 4 s after switching on, or does not lock within 30 s. x Motor locked within 10 s after reversing, or does not lock within 30 s.

x Charge corona wire cleaner motor defective x Motor driver defective



306


C
Charge corona wire cleaner error 2





Charge coronal motor is disconnected. (The current at the charge corona motor is detected less than 83 mA.)

x Charge corona wire cleaner motor connector is defective, connected.




NOTE: When SC310~SC317 are logged, the machine halts without displaying the SC number. These SC codes log an abnormal condition at the potential sensor only
when SP3901 (Auto Process Control) is set to on.



SC No.

Symptom

Possible Cause


310


D
Potential sensor calibration error 1





During drum potential sensor calibration, the drum potential sensor output voltage does not meet specification when test voltages (– 100V, –800V) are applied to the drum.

x Potential sensor defective x Potential sensor harness disconnected
x Potential sensor connector defective or disconnected
x IOB defective x OPC connector defective x Development power pack defective






311


C
Potential sensor calibration error 2





During drum potential sensor calibration, the drum potential sensor output voltage does not meet specification when test voltages (– 100V, –800V) are applied to the drum.

x Potential sensor defective x Potential sensor harness disconnected
x Potential sensor connector defective or disconnected
x IOB defective x OPC connector defective x Development power pack defective



312


C
Potential sensor calibration error 3





During drum potential sensor calibration when adjusting the drum potential (VD), the drum potential sensor detects VD higher than VG (grid voltage).
-or-
When adjusting VD (drum surface potential of black areas after exposure), even after 5 adjustments of VG (charge corona grid potential), VD could not be set in the target range (– 800r10 + VL + 130V)

x Potential sensor defective x Potential sensor harness disconnected
x Potential sensor connector defective or disconnected
x IOB defective x OPC connector defective x Development power pack defective x Charge corona unit worn out, dirty



314


C
Potential sensor calibration error 4





During drum potential sensor calibration when adjusting the drum potential (VH) for LD power adjustment, the first time the VH pattern is made, the drum potential sensor detects that VH is more than 500V:
VH > |–500 + VL + 130| V

x Potential sensor defective x Potential sensor harness disconnected
x Potential sensor connector defective or disconnected
x IOB defective x OPC connector defective x LD defective



315


C
Potential sensor calibration error 5





During drum potential sensor calibration, when –100V is applied to the drum, the output value is out of the prescribed range.

x Potential sensor defective x Potential sensor harness disconnected
x Potential sensor connector defective or disconnected
x IOB defective x OPC connector defective x Development power pack defective



316


C
Potential sensor calibration error 6





During drum potential sensor calibration, when –800V is applied to the drum, the output value is out of the prescribed range.

x Potential sensor defective x Potential sensor harness disconnected
x Potential sensor connector defective or disconnected
x IOB defective x OPC connector defective x Development power pack defective











317


C
Potential sensor calibration error 7



During drum potential sensor calibration, when VL is adjusted, the pattern surface potential VL pattern is not within range 0V ~ –400V. (VL is the potential after exposing a white pattern.)

x Potential sensor defective x Potential sensor harness disconnected
x Potential sensor connector defective or disconnected
x IOB defective x OPC connector defective
x Charge corona power pack defective x Development power pack defective



321


D
F-GATE error

B140 Only



The laser writing signal (F-GATE) for the IPU does not go LOW within 60 s.

x BICU board defective
x PCI bus between controller board,
BICU board defective



322


D
Laser synchronization detector error

B140 Only



After the polygon motor reaches standard rotation speed and the LD unit fires for 500 ms, the laser synchronization detector does not generate a signal.

x Harness between detector and I/F disconnected or damaged
x Detector is installed incorrectly x Detector board is defective x IPU board defective



335


D
Polygon mirror motor error 1

B140 Only



The ready signal does not go low within 20 s after the polygon mirror motor turns on or changes speed.

x Harness between I/F and polygon motor disconnected or defective
x Polygon motor or polygon motor driver defective x IPU board defective



336


D
Polygon mirror motor error 2

B140 Only



The ready signal does not go high within 20 s after the polygonal mirror motor turns off.

x Harness between I/F and polygon motor disconnected or defective
x Polygon motor or polygon motor driver defective x IPU board defective



337


D
Polygonal mirror motor error 3

B140 Only



The XSCRDY signal goes high while the polygon mirror motor turns on, even though there was no request to either turn off the motor or change the motor speed.

x Noise on the line where the polygon ready signal (XSCRDY) is transmitted. x Harness between the polygon motor and I/F disconnected or defective.
x Polygon motor or polygon motor driver defective



338


D
Polygonal mirror motor error 4

B140 Only



While the polygon motor is rotating, the XSCRDY signal goes high during exposure.

x Noise on the linef where the polygon ready signal (XSCRDY) is transmitted. x Harness between the polygon motor and I/F disconnected or defective.
x Polygon motor or polygon motor driver defective x IPU board defective






340


C
TD sensor output error





TD sensor output voltage (Vt), measured during each copy cycle, is detected 10 times at one of the following levels: Vt = 0.5 volts or lower
Vt = 4.0 volts or higher

x TD sensor defective
x TD sensor harness disconnected x TD sensor connector disconnected or defective
x IOB defective
x ریکو آفیشیو TONER ریکو آفیشیو 2051 bottle motor defective
Note: When the TD sensor is defective, the ریکو آفیشیو TONER ریکو آفیشیو 2051 supply is controlled using pixel count and the ID sensor.



341


D
TD sensor adjustment error 1





During the TD sensor auto adjustment, the TD sensor output voltage (Vt) is 2.5 volts or higher even though the control voltage is set to the minimum value (PWM = 0). When this error occurs, SP2-906-1 reads 0.00V.
Note: This SC is released only after correct adjustment of the TD sensor has been achieved. Switching the machine off and on will cancel the SC display, but does not release ID sensor ریکو آفیشیو TONER ریکو آفیشیو 2051 supply.

x TD sensor defective
x TD sensor harness disconnected x TD sensor connector disconnected or defective
x IOB defective
x ریکو آفیشیو TONER ریکو آفیشیو 2051 bottle motor defective
Note: When the TD sensor is defective, the ریکو آفیشیو TONER ریکو آفیشیو 2051 supply is controlled using pixel count and the ID sensor.



342


D
TD sensor adjustment error 2





During the TD sensor auto adjustment, the TD sensor output voltage (Vt) does not enter the target range (3.0 ± 0.1V) within 20 s. When this error occurs, the display of SP2-906-1 reads 0.00V.
Note: This SC is released only after correct adjustment of the TD sensor has been achieved. Switching the machine off and on will cancel the SC display, but does not release ID sensor ریکو آفیشیو TONER ریکو آفیشیو 2051 supply.

x TD sensor defective
x TD sensor harness disconnected x TD sensor connector disconnected or defective x IOB defective



345


D
Development output abnormal





The high voltage applied to the development unit is detected 10 times higher than the upper limit (45%) of
PWM.

x Development power pack defective x Development bias leak due to poor connection, defective connector



350


C
ID sensor error 1





One of the following ID sensor output voltages was detected twice consecutively when checking the ID sensor pattern.
Vsp t 2.5V
Vsg < 2.5
Vsp = 0V
Vsg = 0

x ID sensor defective
x ID sensor harness disconnected x ID sensor connector defective x IOB defective
x ID sensor pattern not written correctly x Incorrect image density x Charge power pack defective x ID sensor dirty











351


C
ID sensor error 2





The ID sensor output voltage is 5.0V and the PWM signal input to the ID sensor is 0 when checking the ID sensor pattern.


x ID sensor defective
x ID sensor harness disconnected x ID sensor connector defective x IOB defective
x ID sensor pattern not written correctly x Incorrect image density x Charge power pack defective x ID sensor dirty



352


C
ID sensor error 3







For 2 s during the ID sensor pattern check, the ID sensor pattern edge voltage is not 2.5V or the pattern edge is not detected within 800 ms.

x ID sensor defective
x ID sensor harness disconnected x ID sensor connector defective x IOB defective
x ID sensor pattern not written correctly x Incorrect image density x Charge power pack defective x ID sensor dirty



353


C
ID sensor error 4





One of the following ID sensor output voltages is detected at ID sensor initialization.
x Vsg < 4.0V when the maximum PWM input (255) is applied to the ID sensor.
x Vsg t 4.0V when the minimum PWM input (0) is applied to the ID sensor.

x ID sensor defective
x ID sensor harness disconnected x ID sensor connector defective x IOB defective
x ID sensor pattern not written correctly x Incorrect image density x Charge power pack defective x ID sensor dirty



354


C
ID sensor error 5





Vsg falls out of the adjustment target (4.0 r 0.2V) during Vsg checking.

x ID sensor defective
x ID sensor harness disconnected x ID sensor connector defective x IOB defective
x ID sensor pattern not written correctly x Incorrect image density x Charge power pack defective x ID sensor dirty



355


C
ID sensor error 6





The Vp value, which measures the reflectivity of the ID sensor pattern, was not in the range of –70V to –400V.

x Potential sensor defective x Potential sensor harness defective x Potential sensor disconnected x IOB defective
x OPC unit connector defective x Charge corona power pack defective x Charge corona wire dirty, broken









SC400: Image Development System (2)



SC No.

Symptom

Possible Cause


401


D
Transfer output abnormal



When the transfer is output, the feedback voltage remains higher than 4V for 60 ms.

x Transfer power pack defective x Transfer current terminal, transfer power pack disconnected, damaged connector



402


D
Transfer output abnormal release det ection



When the transfer is output, there is hardly any feedback voltage within 60 ms even with application of 24% PWM.

x Transfer power pack defective x Transfer unit harness disconnected x Transfer connector loose, defective



430


C
Quenching lamp error



At the completion of auto process control initialization, the potential of the drum surface detected by the potential sensor is more than
–400V, the prescribed value.

x Quenching lamp defective
x Quenching lamp harness disconnected x Quenching lamp connector loose, defective



440


D
Main motor lock



The main motor lock signal remains low for 2 seconds while the main motor is on.

x Drive mechanism overloaded x Motor driver board defective



441


D
Development motor lock



The development motor lock signal remains high for 2 seconds while the development motor is on.

x Drive mechanism overloaded due to ریکو آفیشیو TONER ریکو آفیشیو 2051 clumping in the wasted ریکو آفیشیو TONER ریکو آفیشیو 2051 path x Motor driver board defective



If this SC is returned on a machine in the field, inspect the ریکو آفیشیو TONER ریکو آفیشیو 2051 supply unit coil. If the gear is not damaged replace the coil. If the gear is damaged, the gear shaft is probably deformed, so replace the e ntire unit.



490


D
Main fan error



The main fan motor lock signal goes high for 5 s while the fan is on.

x Fan motor overloaded due to obstruction x Fan connector disconnected



495


D
ریکو آفیشیو TONER ریکو آفیشیو 2051 recycling unit error



Encoder pulse does not change for 3 s after the main motor switches on.

x Waste ریکو آفیشیو TONER ریکو آفیشیو 2051 transport has stopped due to motor overload
x ریکو آفیشیو TONER ریکو آفیشیو 2051 end sensor detective, disconnected



496


D
ریکو آفیشیو TONER ریکو آفیشیو 2051 collection bottle error



The ریکو آفیشیو TONER ریکو آفیشیو 2051 collection bottle set switch remains off when the front door is closed.

x No ریکو آفیشیو TONER ریکو آفیشیو 2051 collection bottle set
x Poor connection of the switch connector



497


D
ریکو آفیشیو TONER ریکو آفیشیو 2051 collection motor error



The ریکو آفیشیو TONER ریکو آفیشیو 2051 collection motor connector set signal remains off for 1 s.

x ریکو آفیشیو TONER ریکو آفیشیو 2051 pump motor defective x Motor connector loose, disconnected




SC500: Feed, Transport, Duplexing, and Fusing Systems



SC No.

Symptom

Possible Cause


501


B
Tray 1 lift malfunction





x The lift sensor is not activated within 10 seconds after the tray lift motor starts lifting the bottom plate. x When the tray lowers, the tray lift sensor does not go off within 1.5 sec.
x Tray overload detected when the tray is set.
x The lower limit sensor of the LCT does not detect the lower limit within 10 sec.

x Tray lift motor defective, disconnected x Paper or other obstacle trapped between tray and motor
x Pick-up solenoid disconnected, blocked by an obstacle
x Too much paper loaded in tray Note (B246)
x At first, the machine displays a message asking the operator to reset the tray.
x This SC will not display until the operator has pulled the tray out and pushed it in 3 times. x If the operator cycles the machine off/on before the 3rd opening and closing of the tray, the 3-count is reset.



502


B
Tray 2 lift malfunction





x The lift sensor is not activated within 10 seconds after the tray lift motor starts lifting the bottom plate. x When the tray lowers, the tray lift sensor does not go off within 1.5 sec.
x Tray overload detected when the tray is set.

x Tray lift motor defective or disconnected x Paper or other obstacle trapped between tray and motor
x Pick-up solenoid disconnected or blocked by an obstacle
x Too much paper loaded in tray Note (B246)
x At first, the machine displays a message asking the operator to reset the tray.
x This SC will not display until the operator has pulled the tray out and pushed it in 3 times. x If the operator cycles the machine off/on before the 3rd opening and closing of the tray, the 3-count is reset.



503


B
Tray 3 lift malfunction





x The lift sensor is not activated within 10 seconds after the tray lift motor starts lifting the bottom plate.
x When the tray lowers, the tray lift sensor does not go off within 1.5 sec.
x Tray overload detected when the tray is set.

x Tray lift motor defective or disconnected x Paper or other obstacle trapped between tray and motor
x Pick-up solenoid disconnected or blocked by an obstacle
x Too much paper loaded in tray Note (B246)
x At first, the machine displays a message asking the operator to reset the tray.
x This SC will not display until the operator has pulled the tray out and pushed it in 3 times.
x If the operator cycles the machine off/on before the 3rd opening and closing of the tray, the 3-count is reset.







504


B
Tray 4 lift malfunction





x The lift sensor is not activated within 10 seconds after the tray lift motor starts lifting the bottom plate. x When the tray lowers, the tray lift sensor does not go off within 1.5 sec.
x Tray overload detected when the tray is set.

x Tray lift motor defective or disconnected x Paper or other obstacle trapped between tray and motor
x Pick-up solenoid disconnected or blocked by an obstacle
x Too much paper loaded in tray Note (B246)
x At first, the machine displays a message asking the operator to reset the tray.
x This SC will not display until the operator has pulled the tray out and pushed it in 3 times. x If the operator cycles the machine off/on before the 3rd opening and closing of the tray, the 3-count is reset.



507


B
LCT feed motor malfunction





One of the following conditions is detected: x The LD signal from the feed motor is detected abnormal for 50 ms after the motor switches on. x At power on, the motor is detected loose or disconnected.

x Feed motor defective
x Feed motor connector disconnected x Obstacle interfering with mechanical movement of motor.




510


B
LCT tray malfunction





One of the following conditions is detected: x When the bottom plate is lifted, the upper limit sensor does not come on for 18 s. x When the bottom plate is lowered, the lower limit sensor does not come on for 18 s.
x After lift begins, the upper limit sensor does not switch on before the pick-up solenoid switches on. x The paper end sensor switches on during lift and the upper limit sensor does not switch on for 2.5 s, and a message prompts user to reset paper.

x Tray lift motor defective or connector disconnected
x Lift sensor defective or disconnected x Pick-up solenoid defective or disconnected x Paper end sensor defective











515


B
Tandem rear fence motor error





One of the conditions is detected: x The return sensor does not switch on within 10 sec. after the rear fence motor switches on.
x The HP sensor does not switch on 10 sec. after the rear fence motor switches on. x The HP sensor and return sensor switch on at the same time.

x Rear fence motor defective or poor connection
x Paper or other obstacle interfering with operation of the sensors
x Paper or other obstacle trapped between tray and motor
x Motor mechanical overload due to obstruction
x Return sensor or HP sensor defective or dirty
Note (B246)
x This problem will not issue the SC code on the operation panel. x The machine will prompt the operator to reset tray by opening and closing it.
x If the problem persists, the machine will display again and the tray cannot be used.



520


C
Duplex jogger motor error 1





When the jogger fence moves to the home position, the jogger HP sensor does not turn on even if the jogger fence motor has moved the jogger fence 153.5 mm.

x Paper or other obstacle has jammed mechanism
x Sensor connector disconnected or defective x Sensor defective



521


C
Duplex jogger motor error 2





When the jogger fence moves from the home position, the jogger fence HP sensor does not turn off even if the jogger motor has moved the jogger fence 153.5 mm.

x Paper or other obstacle has jammed mechanism
x Sensor connector disconnected or defective x Sensor defective



531


D
Fusing exit motor error





The PLL lock signal was low for 2 seconds during motor operation.

x Motor lock caused by physical overload x Motor drive PCB defective



541


A
Fusing thermistor open





The fusing temperature detected by the center thermistor was below 0qC for 7 sec.

x Thermistor open
x Thermistor connector defective x Thermistor damaged, or out of position x Fusing temperature –15% less than the standard input voltage



542


A
Fusing temperature warm-up error





One of the following occurred:
x After power on, or after closing the front door, the hot roller does not reach the 100qC control temperature within 25 s.
x 5 sec. after temperature rise started, temperature remained below 21qC after 5 samplings.
x Fusing unit did not attain reload temperature within 48 sec. of the start of fusing temperature control.

x Fusing lamp disconnected x Thermistor warped, out of position x Thermostat not operating







543


A
Fusing lamp overheat error 1 (software)



Central thermistor detected a temperature of 240qC at the center of the hot roller. Fusing temperature control software error

x PSU defective x IOB defective x BICU defective



544


A
Fusing lamp overheat error 1 (hardw are)



The central thermistor or an end thermistor detected a temperature of 250qC on the hot roller.

x PSU defective x IOB defective x BICU defective



545


A
Fusing lamp overheat error 2



After hot roller reaches warmup temperature, the fusing lamps remained on at full capacity for 11 samplings (1.8 sec. duration) while the hot roller was not rotating.

x Thermistor damaged, or out of position x Fusing lamp disconnected



547


D
Zero cross signal malfunction



One of the following conditions is detected 10 times: x When the main switch is on, the frequency measured by the number of zero cross signals for 500 ms is larger than 66Hz or smaller than 45 Hz. x The interval between one zero cross signal and the next is 7.5 ms or shorter 3 times consecutively for 500 ms.

x Noise on the ac power line



550


A
Fusing Web End



Web end detected 5 times within 500 ms and web motor continues to rotate 40 s. If web end is detected for another 500 ms, then the SC is logged.

x Web end (requires replacement) x Web end sensor defective
Note: After replacing the web with a new one, reset SP1902 001 to "0" to release SC550.




551


A
Fusing thermistor error 1



The end thermistor (contact type) was less than 0C (32F) for more than 7 seconds.

x Thermistor disconnected x Thermistor connector defective



552


A
Fusing thermistor error 2



The end thermistor (contact type) could not detect:
x 100qC 25 seconds after the start of the warmup cycle.
x A change in temperature more than than 16 degrees for 5 seconds.
x The reload temperature with 56 seconds after the start of the fusing temperature control cycle.

x Fusing lamp disconnected x Thermistor bent, damaged x Thermistor position incorrect











553


A
Fusing thermistor error 3





The end thermistor (contact type) was at 240qC (464qF) for more than 1 second. The temperature is read 10 times every sec. (at 0.1 sec. intervals).

x PSU defective
x IOB control board defective x BICU control board defective



555


A
Fusing lamp error





After the start of the warmup cycle, a fusing lamp was at full power for 1.8 seconds but the hot roller did not turn.

x Thermistor bent, out of position x Fusing lamp disconnected x Circuit breaker opened



557



Zero cross signal error

B246



High frequency noise was detected on the power line.

x No action required. The SC code is logged and the operation of the machine is not affected.



559


A
Fusing jam: 3 counts

B246



At the fusing exit sensor the paper was detected late for three pulse counts (lag error), and SP1159 was on.

This SC only occurs if SP1159 is on, and a jam occurred in the fusing unit for three consecutive sheets of paper.
Remove the paper that is jammed in the fusing unit. Then make sure that the fusing unit is clean and has no obstacles in the paper feed path.



569


D
Fusing pressure release motor error





During copying, the HP sensor could not detect the actuator, tried again 3 times and could not detect.

x Motor lock because of too much load x Motor driver defective
x HP sensor defective, disconnected, connector defective, harness damaged



590


D
ریکو آفیشیو TONER ریکو آفیشیو 2051 collection motor error





The ریکو آفیشیو TONER ریکو آفیشیو 2051 collection motor sensor output does not change for 3 seconds while the ریکو آفیشیو TONER ریکو آفیشیو 2051 collection motor is on.

x Motor lock due to obstruction x Motor driver board defective x Motor connection loose, defective x ریکو آفیشیو TONER ریکو آفیشیو 2051 collection motor sensor disconnected, sensor defective
x Rotational transmission shaft (I6 x 30) missing



599


D
1-bin Exit Motor Error (Japan Only)





The transport lock sensor output does not change within 300 ms after the motor switches on.

x Motor overload x Motor driver defective









SC600: Data Communication



SC No.

Symptom

Possible Cause


610


D
BICU Ù ADF communication/timeou t abnormal



After 1 data frame is sent to the ADF, an ACK signal is not received within 100 ms, and is not received after 3 retries.

x Serial line connection unstable x External noise on the line



611


D
BICU Ù ADF communication/break r eception abnormal



During communication a break (Low) signal was received from the ADF.

x Serial line connection unstable x Harness disconnected or defective



612


D
BICU Ù ADF communication/comm and abnormal



A command that cannot be executed was sent from the main machine to the ADF.

x A software error, result of an abnormal procedure.



620


D
BICU Ù ADF communication/timeou t error



After 1 data frame is sent to the finisher MBX, an ACK signal is not received within 100 ms, and is not received after 3 retries.

x Serial line connection unstable x External noise on the line



621


D
BICU Ù Finisher communication/bre ak error



During communication with the finisher MBX, the BICU received a break (Low) signal from the finisher.

x Serial line connection unstable x External noise on the line



623


D
BICU Ù Tray 1~4 communication/ti meout error



After 1 data frame is sent to the trays, an ACK signal is not received within 100 ms, and is not received after 3 retries.

x Serial line connection unstable x External noise on the line



624


D
BICU Ù Tray 1~4 communication/br eak reception error



During communication with the finisher trays, the BICU received a break (Low) signal.

x Serial line connection unstable x External noise on the line



626


D
BICU Ù LCT communication/timeout error



After 1 data frame is sent to the LCT, an ACK signal is not received within 100 ms, and is not received after 3 retries.

x Serial line connection unstable x External noise on the line



627


D
BICU Ù LCT communication/break r eception error



During communication with the LCT, the BICU received a break (Low) signal.

x Serial line connection unstable x External noise on the line






SC650


NRS Modem Communication Error



One of the following factors could be the cause of this error:
x In the User Tools, check the settings for the dial-up user name and dial up password.
x Modem has been disconnected.
x Modem board disconnected.

Check the following for a machine that is using Cumin (NRS modem):
x An error was returned during the dialup connection
x A network was detected at startup x At startup the machine detected that the NIB was disabled, or did not detect a
modem board



NOTE: For more details about this SC code error, execute SP5990 to print an SMC report so you can read the error code. The error code is not displayed on the operation panel. Here is a list of error codes:


Error

Problem

Solution



1

Failure to certify dial-up

In the User Tools, check the dial-up user and dialup password settings



4

Illegal modem setting

Check the setting of SP5816 160 to determine whether the setting for the AT command is correct. If this SP setting is correct, then the problem is a bug in the software.



5

Poor connection due to low power supply on the line.

The problem is on the external power supply line, so there is no corrective action on the machine.



11

Data in the NVRAM became corrupted when the network enable switch and Cumin-M were enabled at the same time.

Use SP5985 1 and set the NIC to "0" (Disable) to disable the network board.



12

The modem board could not enable the NIB.

Replace the modem board.







SC No.

Symptom

Possible Cause


651


Illegal Remote Service Dial-up





An expected error occurred when Cumin-M dialed up the NRS Center.

x Software bug
x No action is required because only the count is logged




670
D

Engine startup error





The machine engine, controlled by the BICU (Base Image Control Unit), was operating incorrectly when the machine was switched on or returned to normal operation from the energy save mode.

x Check the connections between BICU and controller
x BICU defective
x Controller board defective x PSU defective




672
B

Controller startup error





x After power on, the line between the controller and the operation panel did not open for normal operation.
x After normal startup, communication with the controller stopped.

x Controller stalled
x Controller installed incorrectly x Controller board defective
x Operation panel harness disconnected or defective









SC700: Peripherals



SC No.

Symptom

Possible Cause


700


D
ADF original pick-up error 1



Pick-up roller HP sensor signal does not change after the pick-up motor has turned on.

x Pick-up roller HP sensor defective x Pick-up motor defective
x Timing belt slipping, out of position x ADF main board defective



701

D

ADF bottom plate motor error



x Bottom plate position sensor does not detect the plate after the bottom plate lift motor switches on to lift the plate.
x Bottom plate HP sensor does not detect the plate after the bottom plate motor reverses to lower the plate.

x Bottom plate position sensor defective x Bottom plate HP sensor defective x Bottom plate motor defective x ADF main board defective



720

D

Finisher transport motor error



The encoder pulse of the finisher transport motor does not change state (high/low) within 600 ms and does not change after 2 retries.

x Finisher transport motor defective x Transport motor harness disconnected, or defective x Finisher main board defective



721


B
Finisher jogger motor error



x The finisher jogger HP sensor remains de-activated for more 1,000 pulses when returning to home position. x The finisher jogger HP sensor remains activated for more than 1,000 pulses when moving away from home position.

x Jogger HP sensor defective x Jogger mechanism overload x Jogger motor defective (not rotating) x Finisher main board defective x Harness disconnected or defective



723



Feed-Out Belt Motor (B478)

B246



The pawl of the feed-out belt did not return to the home position during the prescribed time after 2 attempts to detect.

x Stack feed-out belt HP sensor loose, broken, defective
x Feed-out belt motor defective x Finisher control board defective



724


B
Finisher staple hammer motor error ( B478)



The staple hammer motor did not return to the home position within the prescribed time (340 ms).

x Staple hammer HP sensor loose, broken, defective
x Electrical overload on the stapler drive
PCB elect x Staple hammer motor defective x Finisher main board defective




B140/B246 Duplicated Number


725


B
Finisher stack feed-out motor error

B140



The stack feed-out belt HP sensor does not activate within the prescribed number of pulses after the stack feed-out motor turns on and does not activate after 2 retries.

x Stack feed-out HP sensor defective x Harness disconnected or defective x Stack feed-out motor defective x Finisher main board defective x Motor overload



725



Exit guide motor

B246



The status of the exit guide sensor did not change at the prescribed time during operation of the exit guide.

x Exit guide open sensor loose, broken, defective. x Exit guide motor defective x Finisher main board defective




B140/B246 Duplicated Number


726


B
Finisher upper tray lift motor error

B140



The paper height sensor does not activate within the prescribed time after the upper tray lift motor turns on, or the sensor remains on after the motor reverses to lower the tray.

x Upper tray paper height sensor defective
x Sensor harness disconnected, defective
x Tray lift motor defective x Finisher main board defective x Tray lift motor overload



726



Front shift jogger motor error (B703)

B246



The sides fences do not retract within the prescribed time after the shift jogger motor switches on. The 1st detection failure issues a jam error, and the 2nd failure issues this SC code.

x Shift jogger motor disconnected, defective
x Shift jogger motor overloaded due to obstruction
x Shift jogger HP sensor disconnected, defective




B140/B246 Duplicated Number


727


B
Finisher stapler rotation motor error

B140



The stapler motor switches on but the motor does not return to the home position within the prescribed number of pulses. After 2 counts, the SC is logged as a jam.

x Stapler rotation motor defective x Poor stapler rotation motor connection x Stapler rotation sensor defective x Finisher main board defective x Rotation motor overload



727


B
Rear shift jogger motor (B703)

B246



The side fences do not retract within the prescribed time after the shift jogger motor switches on. The 1st detection failure issues a jam error, and the 2nd failure issues this SC code.

x Motor harness disconnected, loose, defective
x Motor defective x Motor overload x HP defective






728


B
Shift jogger retraction motor error (B703)

B246



The side fences do not retract within the prescribed time after the retraction motor switches on. The 1st detection failure issues a jam error, and the 2nd failure issues this SC code.

x Motor harness disconnected, loose, defective
x Motor defective x Motor overload x HP defective



729


D
Finisher punch motor error

B140



The punch HP sensor does not activate within the prescribed time after the punch motor turns on.

x Punch HP sensor defective x Sensor harness disconnected, defective
x Punch motor defective x Finisher main board defective x Poor punch motor overload









B140/B246 Duplicated Number


730


B
Finisher stapler movement motor error

B140



The stapler HP sensor does activate within the prescribed time after the stapler motor turns on and moves the stapler away from home position. After 2 counts, the SC is logged as a jam.

x Stapler HP sensor defective x Sensor harness disconnected, defective
x Stapler movement motor defective x Finisher main board defective x Stapler movement motor overload



730


B
Finisher Tray 1 shift motor error

B246



The shift roller HP sensor of the upper tray does not activate within the
prescribed time after the shift tray starts to move toward or away from the home position. The 1st detection failure issues a jam error, and the 2nd failure issues this SC code.

x Shift tray HP sensor of the upper tray disconnected, defective
x Shift tray motor of the upper tray is disconnected, defective
x Shift tray motor of the upper tray overloaded due to obstruction






732


B
Finisher shift roller motor error





The shift roller HP sensor does not activate within the prescribed time after the shift roller motor turns on. After 2 counts, the SC is logged as a jam.

x Shift roller HP sensor defective x Sensor harness disconnected, defective x Shift roller motor defective x Finisher main board defective x Shift roller motor overload



733


D
Finisher lower tray lift motor error





After the lift motor switches on to lift the tray, paper height sensor 2 does not detect the top of the paper stack, or after the motor reverses to lower the stack the top of the stack remains detected (the status of paper height sensor 1 does not change). After 2 counts, the SC is logged as a jam.

x Paper height sensor 1 or 2 defective x Sensor harness disconnected, defective x Tray lift motor defective x Finisher main board defective x Tray lift motor overload






735


B
Finisher pre-stack motor error



x The pre-stack motor starts but does not return to the home position within 400 pulses. After 2 counts, the SC is logged as a jam. x Motor does not return to the home position within 280 pulses immediately before or after prestacking. After 2 counts, the SC is logged as a jam.

x Jogger HP sensor defective x Sensor harnesses disconnected, defective
x Pre-stack motor defective x Finisher main board defective x Pre-stack motor overload



736


B
Finisher paper exit guide plate motor error



The paper exit guide plate motor starts but the paper exit guide plate HP sensor does not activate within 750 ms. After 2 counts, the SC is logged as a jam.

x Guide plate HP sensor defective x Sensor harness disconnected, defective x Paper exit guide plate motor defective x Finisher main board defective x Guide plate motor overload.



737


B
Trimmed staple waste hopper full



The hopper that holds the waste from staple trimming is full.

x Staple waste hopper full x Staple waste sensor defective



738


B
Finisher pressure plate motor error



The pressure plate motor switches on but does not return to the home position within the prescribed time after 2 counts.

x HP sensor defective
x Harness disconnected, defective x Motor defective
x Finisher main board defective x Motor overload



739


B
Finisher folder plate motor error



The folder plate motor turns on but the plate does not return to the home position within the prescribed time for 2 counts.

x Plate HP sensor defective x Harness disconnected, defective x Folder plate motor defective x Finisher main board defective x Folder plate motor overload




B140/B246 Duplicated Number


740


B
Finisher front saddle-stitch stapler motor error

B140



Saddle-stitch stapler motor fails to operate within 450 ms within 2 counts..

x HP sensor defective
x Harness d isconnected, defective x Stapler m otor defective x Finisher m ain board defective x Stapler m otor overload



740


B
Finisher corner stapler motor error

B246



The stapler motor does not switch off within the prescribed time after operating. The 1st detection failure issues a jam error, and the 2nd failure issues this SC code.

x Staple jam
x Number of sheets in the stack exceeds the limit for stapling x Stapler motor disconnected, defective











B140/B246 Duplicated Number


741


B
Finisher rear saddle-stitch stapler motor error

B140



Saddle-stitch stapler motor fails to operate within 450 ms within 2 counts..

x HP senso r defective
x Harness d isconnected, defective x Stapler m otor defective x Finisher main board defective x Stapler m otor overload



741


B
Finisher corner stapler rotation motor error

B246



The stapler does not return to its home position within the specified time after stapling. The 1st detection failure issues a jam error, and the 2nd failure issues this SC code.

x Stapler rotation motor disconnected, defective
x Stapler rotation motor overloaded due to obstruction
x Stapler rotation HP sensor disconnected, defective
















B140/B246 Duplicated Number


742


B
Finisher jogger side fence motor error

B140



The jogger motor turns on but the side fences to not return to the home position within 340 pulses for 2 counts.

x HP sensor s defective
x Harness d isconnected, defective x Motor def ective
x Finisher m ain board defective x Motor ove rload



742


B
Finisher stapler movement motor err or

B246



The stapler HP sensor is not activated within the specified time after the stapler motor turned on. The 1st detection failure issues a jam error, and the 2nd failure issues this SC code.

x Stapler movement motor disconnected, defective
x Stapler movement motor overloaded due to obstruction
x Stapler HP sensor disconnected, defective











B140/B246 Duplicated Number


743


B
Finisher shift motor errors

B140



For the optional jogger unit for the B706 finisher: During the return operation, the shift jogger motor or shift jogger fence lift motor did not return to the home position within the set number of pulses.

x HP sensor of shift jogger motor, harness, connector defective, or motor disconnected
x HP sensor, harness, connector of retraction motor defective, or motor disconnected
x Shift jogger motor defective x Shift jogger fence lift motor defective x Finisher main control board defective




743


B
Booklet stapler motor error 1

B246



The front stapler unit saddle-stitch motor does not start operation within the specified time. The 1st detection failure issues a jam error, and the 2nd failure issues this SC code.

x Front motor disconnected, defective x Front motor overloaded due to obstruction






744


B
Booklet stapler motor error 2

B246



The rear stapler unit saddle-stitch motor does not start operation within the specified time. The 1st detection failure issues a jam error, and the 2nd failure issues this SC code.

x Rear motor disconnected, defective x Rear motor overloaded due to obstruction




B140/B246 Duplicated Number


750


B
Cover interposer bottom plate motor error

B140



x The bottom plate motor turns on to raise the bottom plate but the plate position sensor does not detect the plate within 3 s.
x The bottom plate motor reverses to lower the bottom plate but the bottom plate HP sensor does not detect the plate within 3 s.

x Bottom plate position sensor defective x Bottom plate HP sensor defective x Bottom plate motor defective
x Cover s heet feeder main board defective x Harness es disconnected, defective



750


B
Finisher tray 1 (upper tray lift) motor error

B246



The upper tray paper height sensor does not change its status with the specified time after the tray raises or lowers. The 1st detection failure issues a jam error, and the 2nd failure issues this SC code.

x Tray lift motor disconnected, defective x Upper tray paper height sensor disconnected, defective
x Finisher main board connection to motor loose x Finisher main board defective











B140/B246 Duplicated Number


753


B
Z-Folding unit error 3

B140



The HP sensor of the upper stopper motor does not go off after the stopper moved 128.7 mm.

x Upper stopper motor defective x Upper stopper motor disconnected, connector defective
x Upper stopper motor HP sensor disconnected, defective x Z-Fold main control board defective



753


B
Return roller motor error

B246



Occurs during the operation of the lower tray pressure motor.

x Motor harness disconnected, loose, defective
x Motor overloaded
x Home position sensor harness disconnected, loose, defective x Home position defective









B140/B246 Duplicated Number


754


D
Z-Folding unit error 4

B140



2000 ms after the fan motor switched on, the lock signal did not release.

x Fan motor defective x Fan motor disconnected
x Fan motor locked because of too much load x Z-Fold main control board defective



754



Z-Fold Unit Fan Motor Error

B246



The motor lock signal failed to release within 2 sec. after the Z-fold unit fan motor turned on.

x Fan motor connected loose, broken, defective
x Fan motor defective x Fan blocked by an obstruction






755


B
Z-Folding unit error 5

B140



The fold timing sensor does not operate correctly.

x Paper dust on the sensor x Sensor disconnected, defective x Reflector plate dirty, or out of position x Z-Fold main control board defective



756


B
Z-Folding unit error 6

B140



The leading edge sensor does not operate correctly.

x Paper dust on the sensor x Sensor disconnected, defective x Reflector plate dirty, or out of position x Z-Fold main control board defective



757


B
Z-Folding unit error 7

B140



The machine could not write to the EEPROM two times (one after the other).

x EEPROM defective, replace Z-Fold main control board



760


D
Finisher punch motor error

B246



The punch HP sensor is not activated within the specified time after the punch motor turned on. The 1st detection failure issues a jam error, and the 2nd failure issues this SC code.

x Punch HP sensor disconnected, defective
x Punch motor disconnected, defective
x Punch motor overload due to obstruction



761


B
Finisher folder plate motor error

B246



The folder plate moves but is not detected at the home position within the specified time. The 1st detection failure issues a jam error, and the 2nd failure issues this SC code.

x Folder plate HP sensor disconnected, defective
x Folder plate motor disconnected, defective
x Folder plate motor overloaded due to obstruction.



762


B
Finisher pressure plate motor error

B246



Pressure plate motor operating but the plate is not detected at the home position within the specified time. The 1st detection failure issues a jam error, and the 2nd failure issues this SC code.

x Pressure plate HP sensor disconnected, defective
x Pressure plate motor disconnected, defective
x Pressure plate motor overloaded due to obstruction













763


D
Punch movement motor error

B246



Occurs during operation of the punch unit. The 1st detection failure issues a jam error, and the 2nd failure issues this SC code.

x Motor harness disconnected, loose, defective x Motor defective



764


D
Paper position sensor slide motor error

B246



Occurs during operation of the punch unit. The 1st detection failure issues a jam error, and the 2nd failure issues this SC code.

x Motor harness disconnected, loose, defective x Motor defective



765


B
Folding unit bottom fence lift motor

B246



The 1st detection failure issues a jam error, and the 2nd failure issues this SC code.

x Motor harness disconnected, loose, defective x Motor defective



766


B
Clamp roller retraction motor error

B246



The 1st detection failure issues a jam error, and the 2nd failure issues this SC code.

x Motor harness disconnected, loose, defective x Motor defective



767


B
Stack junction gate motor error

B246



Occurs during operation of the punch unit. The 1st detection failure issues a jam error, and the 2nd failure issues this SC code.

x Motor harness disconnected, loose, defective
x Motor overload x Motor defective



770


B
Cover interposer tray bottom plate motor error

B246



x After the motor starts to raise the bottom plate, the bottom plate position sensor does not detect the plate at the specified time (3 s).
x After the motor starts to lower the bottom plate, the bottom plate HP sensor does not detect the bottom plate.

x Bottom plate position sensor, disconnected, defective
x Bottom plate HP sensor disconnected, defective



780


B
Z-Fold feed motor error

B246



The feed motor does not attain the prescribed speed within the specified time.

x Feed motor disconnected, defective x Feed motor overloaded due to obstruction x Feed motor lock



781


B
Z-Fold lower stopper motor

B246



The lower stopper motor does not attain the prescribed speed within the specified time.

x Lower stopper motor disconnected, defective
x Lower stopper motor overloaded due to obstruction
x Lower stopper HP sensor disconnected, defective



782


B
Z-Fold upper stopper motor

B246



The upper stopper was not detected at the home position after the motor remained on long enough to move it 128.7 mm.

x Upper stopper motor disconnected, defective
x Upper stopper motor overloaded due to obstruction
x Upper stopper HP sensor disconnected, defective













784



Z-fold timing unit fold timing sensor adjustment error

B246



The A/D (Digital/Analog) input value did not change even after the D/A (Digital/Analog) output value changed.

x Fold timing sensor connector loose, broken, defective
x Fold timing sensor defective x Fold timing sensor, mylar covered with paper dust x Mylar disconnected.



785



Z-fold leading edge sensor adjustme nt error

B246



The A/D input value did not change even after the D/A output value changed.

x Leadi ng edge sensor connector loose, broke n, defective
x Leadi ng edge sensor defective x Leadi ng edge sensor, mylar covered with paper dust x Mylar disconnected.



786



Z-fold EEPROM error

B246



The write operation to the Z-folding EEPROM failed after 2 attempts

x EEP ROM defective



790


B
Finisher staple trimming hopper full

B246



The staple waste hopper is full of cut staples.

x If the hopper is full, empty the hopper x If the hopper is not full, the hopper full sensor is disconnected, defective


















SC800: Overall System



SC No.

Symptom

Possible Cause


817

B

Monitor Error





This is a file detection and electronic file signature check error when the boot loader attempts to read the selfdiagnostic module, system kernel, or root system files from the OS Flash ROM, or the items on the SD card in the controller slot are false or corrupted.

x OS Flash ROM data defective; change the controller firmware
x SD card data defective; use another SD card



Error Codes



Code

Meaning


0x0000 0000

BIOS boot error



0x0000 0001

Primary boot start load error



0x0000 0002

Secondary boot load error (Boot3.Elf)



0x0000 0003

Self-diagnostic module error (Diag.Elf



0x0000 0004

Kernel start error (Netbsd)



0x0000 0005

Root file system file read error (Rootfs)



0xffff ffff

Other error



Example: Data in the self-diagnostic module, system kernel, or root system files are corrupted or do not exist in OS flash ROM or on the SD card
Files in the self-diagnostic module, kernel, or root file system on the SD card have been falsified or altered
x Before discarding the SD card, try to update the data on the card. If the error occurs again, the card may be defective. x Be sure to use an SD card that contains the correct electronic signature.




SC No.

Symptom

Possible Cause


818


D
Watchdog error





While the system program is running, a bus hold or interrupt program goes into an endless loop, preventing any other programs from executing.

x System program defective; switch off/on, or change the controller firmware if the problem cannot be solved x Controller board defective x Controller option malfunction



819


D
Fatal kernel error





Due to a control error, a RAM overflow occurred during system processing. One of the following messages was displayed on the operation panel.

x System program defective x Controller board defective x Optional board defective x Replace controller firmware



0x696e

init died





0x766d

vm_pageout: VM is full





4361

Cache Error





Other








NOTE: For more details about this SC code error, execute SP5990 to print an SMC report so you can read the error code. The error code is not displayed on the operation panel.




SC No.

Symptom

Possible Cause


821


D

Self-diagnostic error 2: ASIC



The ASIC provides the central point for the control of bus arbitration for CPU access, for option bus and SDRAM access, for SDRAM refresh, and for management of the internal bus gate.



0B0

Error code 0xffff ffff is returned when the register Write & Verify check is executed on the ASIC mounted on the controller board. The ASIC controls the ROM and buses for other devices.

x ASIC (controller board defective)




0B0
6

ASIC not detected

x ASIC defective
x Poor connection between North Bridge and PCI I/F x Replace controller board



0B1

Failed to initialize or could not read connection bus. Data in SHM register incorrect.

x Connection bus defective x SHM defective x Replace controller board









NOTE: For more details about this SC code error, execute SP5990 to print an SMC report so you can read the error code. The error code is not displayed on the operation panel.





SC No.

Symptom

Possible Cause


822


B
Self-diagnostic error 3: HDD









3003

Check performed when HDD is installed:
x HDD device busy for over 31 s.
x After a diagnostic command is set for Sthe HDD, but the device remains busy for over 6 s A diagnostic command is issued to the HDD device b the result is an erro


.
ut

x HDD defective
x HDD harness disconnected, defective x Controller board defective



3004

No response to the selfdiagnostic command from th
ASIC to the HDDs

e

x HDD defective



3013

Mandolin does not respond, the HDD device remains BUSY for more than 31 s, or the BUSY signal does not drop within 6 s after the diagnostic command is issued to the HDDs.



x HDD defective
x HDD connector loose or defective x Controller defective




SC No.

Symptom

Possible Cause






3014

Error returned from HDD in response to the selfdiagnostic command,
Mandolin could not be located due to a read/write error at the HDD register.

x HDD defective



824


D
Self-dia gnostic error 4: NVRAM



NVRA M device does not exist,
NVRA M device is damaged, NVRAM socket damaged

x NVRAM defective x Controller board defective x NVRAM backup battery exhausted x NVRAM socket damaged



826


D
Self-dia gnostic error 6: NVRAM (option NVRAM)



1501

The difference between the 1 s measured for RTC in the NVRAM and the 1 s timeout of the CPU is out of range, or the NVRAM is not detected.

x NVRAM defective
x NVRAM installed incorrectly




15FE

Backup battery error. Battery is exhausted or not within rated specification.

x The battery is attached permanently to the controller board. Replace the controller board.



828


D
Self-diagnostic error 7: ROM



x Measuring the CRC for the boot monitor and operating system program results in an error.
x A check of the CRC value for ROMFS of the entire ROM area results in an error.

x Software defective x Controller board defective x ROM defective




NOTE: For more details about this SC 833, SC834 error, execute SP5990 to print an SMC report so you can read the error code. The error code is not displayed on the operation panel. The additional error codes (0F30, 0F31, etc. are listed in the SMC report.




SC No.

Symptom

Possible Cause


833


D
Self-diagnostic error 8: Engine I/F A SIC



0F30
0F31



ASIC (Mandolin) for system control could not be detected. After the PCI configuration, the device ID for the ASIC could not be checked.

x ASCI (Mandolin) for system control is defective
x Interface between North Bridge and
AGPI is defective x Replace the mother board



0F41



The read/write check done for resident RAM on the mother board could not be done correctly.

x Memory device defective x Replace the mother board



50B1



Could not initialize or read the bus connection.

x Bus connection defective, loose x SSCG defective x Replace the mother board



50B2



Value of the SSCG register is incorrect.

x Bus connection loose, defective x SSCG defective x Replace the mother board



834


D
Self-diagnostic error 9: Optional Me mory RAM DIMM



5101



The write/verify check for the optional RAM chip on the engine mother board gave an error.

x Controller defective x Mother board defective



850


B
Net I/F error






SC No.

Symptom

Possible Cause






x Duplicate IP addresses. x Illegal IP address.
x Driver unstable and cannot be used on the network.

x IP address setting incorrect x NIB (PHY) board defective
x Controller board defective




851


B
IEEE 1394 I/F error



Driver setting incorrect and cannot be used by the 1394 I/F.

x NIB (PHY), LINK module defective; change the Interface Board x Controller board defective



853


B
Wireless LAN Error 1



During machine start-up, the machine can get access to the board that holds the wireless LAN, but not to the wireless LAN card
(802.11b or Bluetooth).

x Wireless LAN card missing (was removed)



854


B
Wireless LAN Error 2



During machine operation, the machine can get access to the board that holds the wireless LAN, but not to the wireless LAN card
(802.11b or Bluetooth).

x Wireless LAN card missing (was removed)



855


B
Wireless LAN error 3



An error was detected on the wireless LAN card (802.11b or Bluetooth).

x Wireless LAN card defective
x Wireless LAN card connection incorrect



856


B
Wireless LAN error 4



An error was detected on the wireless LAN card (802.11b or Bluetooth).

x Wireless LAN card defective x PCI connector (to the mother board) loose



857


B
USB I/F Error



The USB driver is not stable and caused an error.

x Bad USB card connection x Replace the controller board



860


B
HDD startup error at main power o n



x HDD is connected but a driver error is detected.
x The driver does not respond with the status of the HDD within 30 s.

x HDD is not initialized x Level data is corrupted x HDD is defective



861


D
HDD re-try failure



At power on with the HDD detected, power supply to the HDD is interrupted, after the HDD is awakened from the sleep mode, the HDD is not ready within 30 s.

x Harness between HDD and board disconnected, defective
x HDD power connector disconnected x HDD defective
x Controller board defective














SC No.

Symptom

Possible Cause


863


D
HDD data read failure





The data written to the HDD cannot be read normally, due to bad sectors generated during operation.

x HDD defective
Note: If the bad sectors are generated at the image partition, the bad sector information is written to NVRAM, and the next time the HDD is accessed, these bad sectors will not be accessed for read/write operation.



864


D
HDD data CRC error





During HDD operation, the HDD cannot respond to an CRC error query. Data transfer did not execute normally while data was being written to the HDD.

x HDD defective



865


D
HDD access error





HDD responded to an error during operation for a condition other than those for SC863, 864.

x HDD defective.



866


B
SC card error 1: Confirmation





The machine detects an electronic license error in the application on the SD card in the controller slot immediately after the machine is turned on.
The program on the SD card contains electronic confirmation license data. If the program does not contain this license data, or if the result of the check shows that the license data in the program on the SD card is incorrect, then the checked program cannot execute and this SC code is displayed.

x Program missing from the SD card x Download the correct program for the machine to the SD card



867


D
SD card error 2: SD card removed





The SD card in the boot slot when the machine was turned on was removed while the machine was on.

x Insert the SD card, then turn the machine off and on.



868


D
SD card error 3: SC card access





An error occurred while an SD card was used.

x SD card not inserted correctly x SD card defective
x Controller board defective
Note: If you want to try to reformat the SC card, use SD Formatter Ver 1.1.







870


B
Address book data error



Address book data on the hard disk was detected as abnormal when it was accessed from either the operation panel or the network. The address book data cannot be read from the HDD or SD card where it is stored, or the data read from the media is defective.

x Software defective. Turn the machine off/on. If this is not the solution for the problem, then replace the controller firmware.
x HDD defective.



More Details
x Do SP5846 050 (UCS Settings – Initialize all Directory Info.) to reset all address book data. x Reset the user information with S P5832 006 (HDD Formatting– User Information).
x Replace the HDDs. x Boot the machine from the SD ca rd.



873


B
HDD mail send data error



An error was detected on the HDD immediately after the machine was turned on, or power was turned off while the machine used the HDD.

x Do SP5832-007 (Format HDD – Mail TX Data) to initialize the HDD.
x Replace the HDD



874


D
Delete All error 1: HDD



A data error was detected for the HDD/NVRAM after the Delete All option was used.
Note: The source of this error is the Data Overwrite Security Unit B660 running from an SD card.

x Turn the main switch off/on and try the operation again. x Install the Data Overwrite Security Unit again. For more, see section “1.
Installation”.
x HDD defective



875


D
Delete All error 2: Data area



An error occurred while the machine deleted data from the HDD.
Note: The source of this error is the Data Overwrite Security Unit B660 running from an SD card.

x Turn the main switch off/on and try the operation again.



880


D
File Format Converter (MLB) error



A request to get access to the MLB was not answered within the specified time.

x MLB defective, replace the MLB









SC900: Miscellaneous



SC No.

Symptom

Possible Cause


900


D
Electrical total counter error

B140



The total counter contains something that is not a number.

x NVRAM incorrect type x NVRAM defective x NVRAM data scrambled
x Unexpected error from external source



901


D
Mechanical total counter error



The mechanical counter is not connected.

x Mechanical total counter defective x Mechanical total counter connector not connected



910


D


External Controller Error 1


B140/B246


911


D


External Controller Error 2



912


D


External Controller Error 3



913


D


External Controller Error 4



914


D


External Controller Error 5









The external controller alerted the machine about an error.

x Please refer to the instructions for the external controller.



919


B


External Controller Error 6 B140/ B246



While EAC (External Application Converter), the conversion module, was operating normally, the receipt of a power line interrupt signal from the FLUTE serial driver was detected, or BREAK signal from the other station was detected.

x Power outage at the EFI controller x EFI controller was rebooted x Connection to EFI controller loose



920


B


Printer error 1

B140



An internal application error was detected and operation cannot continue.

x Software defective; turn the machine off/on, or change the controller firmware x Insufficient memory



921


B


Printer error 2

B140



When the application started, the necessary font was not on the SD card.

x Font not on the SC card








SC No.

Symptom

Possible Cause


925


B
NetFile Function Error





x The NetFile file management on the HDD cannot be used, or a NetFile management file is corrupted and operation cannot continue.
x The HDDs are defective and they cannot be debugged or partitioned, so the Scan Router functions (delivery of received faxes, document capture, etc.), Fabric services, and other network functions cannot be used.( HDD status codes displayed on the debug console are described below.)

x HDD defective x Power supply to machine cut occurred while writing data to HDD
x Software error x Please refer to the detailed descriptions below for recovery procedures.



HDD Status Codes Displayed on Debug Console


Display


Meaning



(-1)
HDD not connected




(-2)
HDD not ready




(-3)
No level




(-4)
Partition type incorrect




(-5)
Error returned during level read or check




(-6)
Error returned during level read or check




(-7)
“filesystem” repair failed




(-8)
“filesystem” mount failed




(-9)
Drive does not answer command




(-10)
Internal kernel error




(-11)
Size of drive is too small




(-12)
Specified partition does not exist




(-13)
Device file does not exist



Recovery Procedure 1





If the machine returns SC codes for HDD errors (SC860 ~ SC865), please follow the recovery procedures described for these SC codes.
Recovery Procedure 2
If the machine does not return one of the five HDD errors (SC860 ~ SC865), cycle the machine off and on. If this does not solve the problem, then initialize the NetFile partition on the HDD with SP5832 011 (HDD Formatting – Ridoc I/F).
NetFiles: Jobs printed from the document server using a PC and DeskTopBinder Before initializing the NetFile partition on the HDD please inform the client that:


Received faxes on the delivery server will be lost
All captured documents will be lost
DeskTopBinder/Print Job Manager/Desk Top Editor job history will be cleared
Documents stored on the document server, included scanned documents, will not be lost.
The first time the network accesses the machine, the management information must be reconfigured (this will require a significant amount of time).

Before initializing the Netfile partition with SP5823 011, do the following:


Enter the User Tools mode and execute “Delivery Settings” to print all received fax documents scheduled for delivery and delete them.
In the User Tools mode, execute Document Management> Batch Delete Transfer Documents.
Execute SP5832 011 then cycle the machine off and on. Recovery Procedure 3

If “Procedure 2” does not solve the problem, execute SP5832 001 (HDD Formatting – All), then cycle the machine off and on.
Executing SP5832 001 erases all document and address book data stored on the hard disks. Be sure to consult with the customer before executing this SP code.
Recovery Procedure 4
If “Recovery Procedures 1 to 3” fail to correct the problem, replace the HDD.




SC No.

Symptom

Possible Cause


953


D
Scanner image setting error



The settings required for image processing using the scanner are not sent from the IPU.

x Software defective



954


D
Printer image setting error



The settings required for image processing using the printer controller are not sent from the IPU.

x Software defective



955


D
Memory setting error



The settings that are required for image processing using the memory are not sent from the IPU.

x Software defective



964


D
Printer ready error



The print ready signal is not generated for more than 17 seconds after the IPU received the print start signal.

x Software defective



984


D
Print image data transfer error



After a data transfer begins from the controller to the engine via the PCI bus, the transfer does not end within 15 s.

x Controller (SIMAC) board defective x BICU defective
x BICU Ù controller disconnected



985


D
Scanned image data transmission er ror



After a data transfer begins from the engine to the controller via the PCI bus, the transfer does not end within 3 s.

x Controller (SIMAC) board defective x BICU defective
x BICU Ùcontroller disconnected



986


D
Software error 1



The write parameter received by the write module at the beginning of the setting table is NULL.

x Controller (SIMAC) board defective x BICU defective
x BICU Ù controller disconnected



990


D
Software error 2

B140




SC No.

Symptom

Possible Cause






The software performs an unexpected function and the program cannot continue.

x Software defective, re-boot*1




991


C
Software error 3

B140



The software performs an unexpected function and the program cannot continue. However, unlike SC990, recovery processing allows the program to continue.

x Software defective, re-boot*1




*1: In order to get more details about SC990 and SC991:
3) Execute SP7403 or print an SMC Report (SP5990) to read the history of the 10 most recent logged errors.





4) If you press the zero key on the operation panel with the SP selection menu displayed, you will see detailed information about the recently logged SC990 or SC991, including the software file name, line number, and so on. 1) is the recommended method, because another SC could write over the information for the previous SC.




SC No.

Symptom

Possible Cause



992

D
Software error 4: Undefined

B140



An error not controlled by the system occurred (the error does not come under any other SC code).

x Software def ective
x Turn the mac hine power off and on. The machine can not be used until this error is cleared.



SC994


C
Operation Panel Management Rec ords Exceeded

B246



An error occurred because the number of records exceeded the limit for images managed in the service layer of the firmware. This can occur if there if there are too many application screens open on the operation panel.

x No action req uired because this SC does not interfere with operation of the machine.




997

B
Cannot select application function

B140



An application does not start after the user pushed the correct key on the operation panel.

x Software bug
x A RAM or DI MM option necessary for the application is not installed or not installed correctly.




998

D
Application cannot start

B140



Register processing does not operate for an application within 60 s after the machine power is turned on. No applications not start correctly, and all end abnormally.

x Software bug
x A RAM or DIMM option necessary for the application is not installed or not installed correctly.












4.3.4 JAM CODES
Here are lists of SC codes that are printed in the SMC report; they do not appear on the operation panel display.
Main Unit: Paper Jam Errors


No.


Check-In Failure (Paper Does Not Arrive)
No.


Check-Out Failure (Paper Remains)



1
Initial Jam (Power On)








3
Tray 1 feed sensor


53
Tray 1 feed sensor




4
Tray 2 feed sensor


54
Tray 2 feed sensor




5
Tray 3 feed sensor


55
Tray 3 feed sensor




6
Tray 4 feed sensor (Japan Only)


56
Tray 4 feed sensor (Japan Only)




7
LCT feed sensor


57
LCT feed sensor




8
Transport sensor 1


58
Transport sensor 1




9
Transport sensor 2


59
Transport sensor 2




10
Transport sensor 3


60
Transport sensor 3




11
Transport sensor 4 (Japan Only)


61
Transport sensor 4 (Japan Only)




12
Relay sensor


62
Relay sensor




13
Registration sensor


63
Registration sensor




14
Fusing exit sensor








15
Exit unit entrance sensor








16
Exit unit


66
Exit unit




19
Exit unit entrance sensor


69
Exit unit entrance sensor




20
Duplex transport sensor 1








21
Duplex transport sensor 2


71
Duplex transport sensor 2




22
Duplex transport sensor 3


72
Duplex transport sensor 3




23
Duplex inverter sensor


73
Duplex inverter sensor




24
1-Bin tray (Japan Only)


74
1-Bin tray (Japan Only)




34
Bypass paper end sensor








Finisher B469 Jam Codes



No.

Location

Related SC Code



101
Entrance Sensor






102
Proof Tray Exit Sensor






103
Exit Sensor






104
Staple Entrance Sensor






105
Exit Sensor after jogging






106
Stapler Unit 1






109
Shift Motor


SC733



110
Jogger Fence Motor


SC722



111
Shift Roller or Guide Plate Motor


SC732, SC736



112
Stapler Movement or Stapler Rotation Motor


SC727, SC730



113
Stapler Unit 2


SC724



115
Feed Out Belt Motor


SC725



116
Punch Hole Motor


SC729



Finisher B468/B674 Jam Codes
No. Location Related SC Code
121 Entrance Sensor
122 Proof Tray Exit Sensor
123 Exit Sensor
124 Staple Entrance Sensor 125 Exit Sensor after jogging
126 Stapler Unit 1
127 Saddle Stitch Stapler Unit
128 Saddle Stitch Stapler Unit
129 Shift Motor SC733, SC726 130 Jogger Fence Motor SC722
131 Shift Roller or Guide Plate Motor SC732, SC736
132 Stapler Movement or Stapler Rotation Motor SC727, SC730
133 Stapler Unit 2 SC724, SC728, SC740,

SC741 134 Folder Plate Motor SC739 135 Feed Out Belt Motor SC725 136 Punch Hole Motor SC729

Finisher B478/B706 Jam Codes



No.

Location

Related SC Code



141
Entrance Sensor






142
Proof Tray Exit Sensor






143
Exit Sensor






144
Staple Entrance Sensor






145
Exit Sensor after jogging






148
Upper Transport Motor






149
Shift Motor


SC733, SC726



150
Jogger Fence Motor


SC722



151
Shift Roller or Guide Plate Motor


SC732, SC736



153
Stapler Unit

SC724, SC738, SC740, SC741




155
Feed Out Belt Motor


SC725



156
Punch Hole Motor


SC729



158
Z-Fold Jogger Motor (B706 Only)






Mailbox B471 Jam Codes



No.

Location

Related SC Code



161
Vertical Transport Sensor 1 (CN201)


---



162
Vertical Transport Sensor 2 (CN204)


---



163
Vertical Transport Sensor 3 (CN209)


---



164
Vertical Transport Sensor 4 (CN2014)


---



165
Vertical Transport Sensor 5 (CN2019)


---



Cover Interposer Tray B470 Jam Codes



No.

Location

Related SC Code


166

Feed or Pull-out Sensor


---


167

Exit Sensor


---


168

Bottom Plate Position Sensor


SC750









Z-Folding Unit B660 Jam Codes



No.

Location


Related SC Code



169

Paper Feed Sensor: Paper Late

---





170

Paper Feed Sensor: Paper Remains



---



171

Fold Timing Sensor: Paper Late



---



172

Fold Timing Sensor: Paper Remains



---



173

Leading Edge Exit Sensor: Paper Late



---



174

Leading Edge Exit Sensor: Paper Remains



---



175

Upper Stopper Path Sensor: Paper Late



---



176

Upper Stopper Path Sensor: Paper Remains



---



177

Lower Exit Sensor: Paper Late



---



178

Lower Exit Sensor: Paper Remains



---



181

Upper Exit Sensor: Paper Late



---



182

Upper Exit Sensor: Paper Remains



---



183

Paper Fold Motor Lock



---



184

Lower Stopper Motor Lock



---



185

Upper Stopper Motor Lock



---





4.3.5 ADDITIONAL SC CODES PRINTED IN SMC REPORT
These codes are also used in the SMC report.
Codes that have the same number in this series are identified by an additional 4digit hexadecimal number.



SC No.

Symptom

Possible Cause


820

0001

TLB conversion (store) exception error

Unexpected error in CPU device: x Controller board defective x Boot monitor or self-diagnostic program corrupted



820

0002

TLB miss (load) exception error



820

0003

TLB miss (store) exception error



820

0004

Read address exception error



820

0005

Write address exception error



820

0006

Command bus exception error



820

0007

Data bus exception error



820

0008

System call exception error



820

0009

Break exception error



820

000A

Illegal command exception error



820

000B

Potential sensor exception error



820

000C

Overflow exception error



820

000D

UTLB miss exception error



820

0010

Allocation 0 error



820

0011

Allocation 1 error



820

0012

Allocation 2 error



820

0013

Allocation 3 error



820

0014

Allocation 4 error



820

0015

Allocation 5 error



820

00FF

Non-initialization allocation error

x CPU defective x Local bus defective x Controller board defective



820

0601

Read address exception error

x CPU device error x Controller board defective



820

0602

Write address exception error



820

0605

System call exception error



820

0606

Break point exception error



820

0607

Illegal command exception error



820

060A

Allocation 0 mask exception error

x CPU device error x ASIC device error x Controller board defective



820

060B

Allocation 1 mask exception error



820

060C

Allocation 2 mask exception error



820

060D

Allocation 3 mask exception error



820

060E

Allocation 4 mask exception error



820

0610

CPU timer 2 allocation set error

x CPU device error x Controller board defective



820

0612

ASIC allocation error

x ASIC device error x Controller board defective x Peripheral device defective



820

06FF

CPU master clock error

x CPU device error
x Error in CPU initialization data (ASIC error) x Controller board defective






SC No.

Symptom

Possible Cause


820

0702

Command cache error

x CPU cache defective x Controller board defective x Memory error (insufficient speed)



820

0709

Data cache error

x CPU device error
x Boot mode setting for CPU error x Controller defective x Insufficient memory



820

070A

Data cache clear error



820

0801

TLB virtual address error

x CPU device defective (controller board defective)



820

0804

TLB global error



820

0807

UTLB miss error



820

0808

TLB read miss error



820

0809

TLB write miss error



820

080A

TLB mode file error



820

4002

Single-precision calculation error

x CPU error (controller board defective)



820

4003

Double-precision calculation error



820

4004

Exception error



820

4005

Exception mask error



822

3003

HDD timeout

x HDD defective
x HDD connector disconnected, defective x ASIC device error (controller board defective)



822

3004

Self-diagnostic command error

x HDD defective



823

6101

MAC address SUM error

x NIB (PHY) board defective x Controller board defective



823

6104

PHY chip ID illegal



823

6105

PHY loopback error



824

1401

NVRAM verify error

x NVRAM defective



826

1501

Clock error

x Optional NVRAM defective



826

15FF

RTC non-detection error

x Incompatible NVRAM installed x NVRAM battery defective



826

0201

Resident memory verify error

x Memory on controller board defective x RAM DIMM defective



828

0101

Boost trap code (CODE) error

x Software storage error (re-install software) x Controller board defective



828

0104

ROM FS error

x ROM device error



828

0105

Forgery prevention error

x Forgery prevention chip defective x Forgery prevention chip error
x Replace the controller, ROM, or RAM DIMM



829

0301

Option memory 0 verify error

x Controller board internal memory error x RAM DIMM defective



829

0302

Option memory 0 configuration information error



835

1102

Verify error

x Loopback connector error (controller board defective)



835

110C

DMA verify error

x Loopback connector error x Controller board defective



835

1120

Loopback connector nondetection

x Loopback connector not set x Loopback connector error x Controller board defective



836

1601

Font ROM 0 error



837

1602

Font ROM 1 error



838

2701

Verify error













SC No.

Symptom

Possible Cause



853
D

IEEE802 11b card startup error



Not used.






854
D

IEEE802 11b card access error



Not used.






855
D

IEEE802 11b card error



Not used.






856
D

IEEE802 11b card connection board e rror



Not used.






870
B

Address book data error



The address book in the hard disk is accessed. o An error is detected in the address book data; address book data is not read; or data is not written into the address book.
NOTE: To recover from the error, do any of the following countermeasures:
Format the address book by using SP5-832-008 (all data in the address book–including the user codes and counters–is initialized)
Initialize the user data by using SP5832-006 and -007 (the user codes and counters are recovered when the main switch is turned on). Replace the hard disk (the user codes and counters are recovered when the main switch is turned on).

x Data corruption x Defective hard disk
x Defective software




920

D

Printer error



The printer program cannot be continued.

x Defective hardware x Data corruption x Defective software



925

D

Net file error



The management file for net files is corrupted; net files are not normally read.
Netfiles: Jobs to be printed from the document server using a PC and the DeskTopBinder software

x Defective hardware x Data corruption x Defective software



992

C

Other system SCs



The controller received an unknown SC code from the engine.

x Contact your product specialist.



993

D

Network error



The ASIC program of GW controller cannot be continued.

x Defective ASIC x Defective GW controller












OTHER PROBLEMS (B064/B140/B246 SERIES)
4.4 OTHER PROBLEMS (B064/B140/B246 SERIES) 4.4.1 BLOWN FUSE CONDITIONS




Fuse

Rating

Symptom at Power On



115 V

210~230V


FU1


2A/125V

6.3A/250V
Anti-condensation heater does not operate.



FU101


12A/125V

6.3A/250V
No response.



FU103


6.3A/125V

6.3A/250V
SC510 is displayed.



FU104


6.3A/125V

6.3A/250V
Nothing displayed on LCD.



FU105


6.3A/125V

6.3A/250V
“Door Open” is displayed.



FU106


6.3A/125V

6.3A/250V
ADF does not operate.



FU107


6.3A/125V

6.3A/250V
SC121 is displayed.



FU108


6.3A/125V

6.3A/250V
Finisher does not work.



FU109


6.3A/125V

6.3A/250V
“Door Open” is displayed.



FU110


6.3A/125V

6.3A/250V
SC510 is displayed.



FU111


6.3A/125V

6.3A/250V
Nothing is displayed on LCD.




4.4.2 COMMON PROBLEMS




Problem

Check

Inspect, Clean, Replace


Dirty Copies

Fusing Unit

Pressure roller



Jam – Fusing Unit

Fusing Unit

Hot roller



Jam – Fusing Unit

Fusing Unit

Hot roller strippers



Jam – Original

ADF

Pick-up, paper feed, separation rollers



Lines (black or white)

Around the Drum

Cleaning blade, cleaning brush



Misfeed – Fusing Unit

Fusing Unit

Hot roller



Offset

Fusing Unit

Hot roller



Poor separation

Transfer Belt Unit

Transfer belt, transfer belt cleaning blade



SC300 ~ SC306

Around the Drum

Charge corona wire, charge corona grid, charge corona wire cleaner.



Skew – Original

ADF

Pick-up, paper feed, separation rollers



ریکو آفیشیو TONER ریکو آفیشیو 2051 on transfer belt

Transfer Belt Unit

Transfer belt, transfer belt cleaning blade



Wrinkling

Fusing Unit

Pressure roller